Impact of cone-beam computed tomography artifacts on dose calculation accuracy for lung cancer

MEDICAL PHYSICS(2024)

引用 0|浏览0
暂无评分
摘要
BackgroundTo implement image-guided adaptive radiotherapy (IGART), many studies investigated dose calculations on cone-beam computed tomography (CBCT). A high HU accuracy is crucial for a high dose calculation accuracy and many imaging sites showed satisfactory results. It has been shown that the dose calculation accuracy for lung cancer lags behind.PurposeTo examine why the dose calculation accuracy for lung is insufficient, the relative effects of the field-of-view (FOV), breathing motion, and scatter on dose calculation accuracy were studied.MethodsA framework was built to simulate CBCT scans for lung cancer patients by forward projecting repeat CT (rCT) scans for two scan geometries: small (SFOV) and medium FOV (MFOV). Breathing motion was modeled by applying a 4D deformation vector field to the mid-position rCT. Scatter was modeled by Monte-Carlo simulations with/without an anti-scatter grid (ASG). Simulated projections were reconstructed using filtered back-projection with/without scatter correction. In case of the SFOV, the CBCT images were patched with the planning CT scan in axial direction. The treatment plan was recalculated on the rCT and simulated CBCT. The mean Hounsfield unit (HU) difference (Delta HUmean), the structural similarity index measure (SSIM), and gamma metrics were calculated for the CBCT datasets of various imaging settings.ResultsThe differences in HU, SSIM and dose calculation accuracy for CBCTs with and without breathing motion were negligible (mean Delta HUmean = 6.4 vs. 13.7, mean SSIM = 0.941 vs. 0.957, mean gamma (ref = MFOV) = 0.75). The SFOV resulted in a lower HU (mean Delta HUmean = -9.2 vs. 13.7) and SSIM (mean SSIM = 0.912 vs. 0.957), and therefore in dose differences compared to the MFOV (mean gamma = 1.22). Scatter led to considerable discrepancies in all metrics. Adding only the ASG improved the results more than only applying a scatter correction algorithm. Combining ASG and scatter correction algorithm resulted in an even higher dose calculation accuracy.ConclusionsScatter and FOV are the main contributors to dose inaccuracies and motion has only a minor effect on dose calculation accuracy. Therefore, utilizing an appropriate scatter correction and FOV is important to achieve sufficient dose calculation accuracy to facilitate IGART for lung.
更多
查看译文
关键词
cone beam CT,dose calculation,image quality,lung cancer,Monte-Carlo
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要