To evaluate the technical success and outcomes of renal biopsies performed under magnetic resonance imaging (MRI) using a closed-bore, 1.5-Tesla MRI unit. We retrospectively reviewed our institutional biopsy database and included 150 consecutive MRI-guided biopsies for renal masses between November 2007 and March 2020. We recorded age, sex, BMI, tumor characteristics, RENAL nephrometry score, MRI scan sequence, biopsy technique, complications, diagnostic yield, pathologic outcome, and follow-up imaging. Univariate logistic regression was used to assess the association between different parameters and the development of complications. McNemar’s test was used to assess the association between paired diagnostic yield measurements for fine-needle aspiration and core samples. A total of 150 biopsies for 150 lesions were performed in 150 patients. The median tumor size was 2.7 cm. The median BMI was 28.3. The lesions were solid, partially necrotic/cystic, and predominantly cystic in 137, eight, and five patients, respectively. Image guidance using fat saturation steady-state free precession sequence was recorded in 95