Comparison of Free-Breathing 3D Phase-Resolved Functional Lung (PREFUL) MRI With Dynamic 19F Ventilation MRI in Patients With Obstructive Lung Disease and Healthy Volunteers

JOURNAL OF MAGNETIC RESONANCE IMAGING(2024)

引用 0|浏览0
暂无评分
摘要
Background: Non-contrast-enhanced (1) H magnetic resonance imaging (MRI) with full lung coverage shows promise for assessment of regional lung ventilation but a comparison with direct ventilation measurement using (19) F MRI is lacking.Purpose: To compare ventilation parameters calculated using 3D phase-resolved functional lung (PREFUL) MRI with (19) F MRI.Study type: Prospective.Population: Fifteen patients with asthma, 14 patients with chronic obstructive lung disease, and 13 healthy volunteers.Field strength/sequence: A 3D gradient-echo pulse sequence with golden-angle increment and stack-of-stars encoding at 1.5 T.Assessment: All participants underwent 3D PREFUL MRI and (19) F MRI. For 3D PREFUL, static regional ventilation (RVent) and dynamic flow-volume cross-correlation metric (FVL-CM) were calculated. For both parameters, ventilation defect percentage (VDP) values and ventilation defect (VD) maps (including a combination of both parameters [VDPCombined ]) were determined. For (19) F MRI, images from eight consecutive breaths under volume-controlled inhalation of perfluoropropane were acquired. Time-to-fill (TTF) and wash-in (WI) parameters were extracted. For all (19) F parameters, a VD map was generated and the corresponding VDP values were calculated.Statistical tests: For all parameters, the relationship between the two techniques was assessed using a Spearman correlation (r). Differences between VDP values were compared using Bland-Altman analysis. For regional comparison of VD maps, spatial overlap and S & oslash;rensen-Dice coefficients were computed.Results: 3D PREFUL VDP values were significantly correlated to VDP measures by (19) F (r range: 0.59-0.70). For VDPRVent , no significant bias was observed with VDP of the third and fourth breath (bias range = -6.8:7.7%, P range = 0.25:0.30). For VDPFVL-CM , no significant bias was found with VDP values of fourth-eighth breaths (bias range = -2.0:12.5%, P range = 0.12:0.75). The overall spatial overlap of all VD maps increased with each breath, ranging from 61% to 81%, stabilizing at the fourth breath.Data conclusion: 3D PREFUL MRI parameters showed moderate to strong correlation with (19) F MRI. Depending on the 3D PREFUL VD map, the best regional agreement was found to (19) F VD maps of third-fifth breath.
更多
查看译文
关键词
ventilation,lung,COPD,asthma
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要