Influence of Early Versus Delayed Hepatic Artery Perfusion Scan on 90Y Selective Internal Radiation Therapy Planning

CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS(2024)

引用 0|浏览4
暂无评分
摘要
Purpose: The aim of this study was to evaluate the effect of an increase in the time interval between hepatic intra-arterial injection of 99mTc-macroaggregated albumin (MAA) and hepatic artery perfusion scintigraphy (HAPS) on the lung shunt fraction (LSF) and perfused volume (PV) calculations in the treatment planning of selective internal radiation therapy (SIRT).Methods: The authors enrolled 51 HAPS sessions from 40 patients diagnosed with primary or metastatic liver malignancy. All patients underwent scan at the first and fourth hour after hepatic arterial injection of 99mTc-MAA. Based on single-photon emission computed tomography images, LSF values were measured from each patient's first and fourth hour images. PV1 and PV4 were also calculated based on three-dimensional images using 5% and 10% cutoff threshold values and compared with each other.Results: The authors found that the median of LSF4 was statistically significantly higher than LSF1 (3.05 vs. 4.14, p <= 0.01). There was no statistically significant difference between PV1 and PV4 on the 10% (p = 0.72) thresholds.Conclusions: LSF values can be overestimated in case of delayed HAPS, potentially leading to treatment cancellation due to incorrectly high results in patients who could benefit from SIRT. Threshold-based PV values do not significantly change over time; nevertheless, keeping the short interval time would be safer.
更多
查看译文
关键词
lung shunt fraction,TARE,spillover,SPECT
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper