Analytical and clinical validation of a multiplex PCR assay for detection of Neisseria gonorrhoeae and Chlamydia trachomatis including simultaneous LGV serotyping on an automated high-throughput PCR system

MICROBIOLOGY SPECTRUM(2024)

引用 0|浏览3
暂无评分
摘要
For effective infection control measures for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG), a reliable tool for screening and diagnosis is essential. Here, we aimed to establish and validate a multiplex PCR assay on an automated system using a dual-target approach for the detection of CT/NG and differentiation between lymphogranuloma venereum (LGV) and non-LGV from genital and extra-genital specimens. Published primer/probe sets (CT: pmpH, cryptic plasmid; NG: porA, opa) were modified for the cobas 5800/6800/8800. Standards quantified by digital PCR were used to determine linearity and lower limit of detection (LLoD; eSwab, urine). For clinical validation, prospective samples (n = 319) were compared with a CE-marked in vitro diagnostics (CE-IVD) assay. LLoDs ranged from 21.8 to 244 digital copies (dcp)/mL and 10.8 to 277 dcp/mL in swab and urine, respectively. A simple linear regression analysis yielded slopes ranging from -4.338 to -2.834 and Pearson correlation coefficients from 0.956 to 0.994. Inter- and intra-run variability was <0.5 and <1 cycle threshold (ct), respectively. No cross-reactivity was observed (n = 42). Clinical validation showed a sensitivity of 94.74% (95% confidence interval (CI): 87.23%-97.93%) and 95.51% (95% CI: 89.01%-98.24%), a specificity of 99.59% (95% CI: 97.71%-99.98%) and 99.57% (95% CI: 97.58%-99.98%), positive predictive values of 89.91% (estimated prevalence: 3.7%; 95% CI: 80.91%-95.6%) and 88.61% (estimated prevalence: 3.4%; 95% CI: 80.18%-94.34%), and negative predictive values of 99.81% (95% CI: 98.14%-100%) and 99.85% (95% CI: 98.14%-100%) for the detection of CT and NG, respectively. In conclusion, we established a dual-target, internally controlled PCR on an automated system for the detectiwon of CT/NG from genital and extra-genital specimens. Depending on local regulations, the assay can be used as a screening or a confirmatory/typing assay. IMPORTANCE Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) represent a major global health burden, with the World Health Organization estimating that >128 million and >82 million people, respectively, were newly infected in 2020. For effective infection control measures, a reliable tool for sensitive diagnosis and screening of CT/NG is essential. We established a multiplex PCR assay for the detection of CT/NG and simultaneous discrimination between lymphogranuloma venereum (LGV) and non-LGV strains, which has been validated for genital and extra-genital specimens on a fully automated system. To increase assay sensitivity, a dual-target approach has been chosen for both pathogens. This strategy reduces false-positive results in oropharyngeal swabs due to the detection of commensal N. species that may harbor NG DNA fragments targeted in the PCR due to horizontal gene transmission following previous infection. In sum, the established assay provides a powerful tool for use as either a screening/diagnostic or a typing/confirmatory assay.
更多
查看译文
关键词
multiplex PCR,high throughput,dual-target PCR,sexually transmitted disease,Chlamydia trachomatis,lymphogranuloma venereum,Neisseria gonorrhoeae,LGV serotyping
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要