Determination of ultra-trace level 241Am in marine sediment and seawater by combining TK200-TK221 tandem-column extraction chromatography and SF ICP-MS

TALANTA(2024)

引用 0|浏览4
暂无评分
摘要
Sound strategies for marine chemical monitoring call for measurement systems capable of producing comparable analytical results with demonstrated quality. This work presents the development and validation of a new analytical procedure for the determination of the 241Am mass fraction in marine sediment and seawater samples at low levels. The procedure includes a tandem -column extraction chromatography for separation of 241Am and sector field -inductively coupled plasma mass spectrometry (SF ICP-MS) for its determination. The separation is based on the application of two new extraction resins, TK200 and TK221. The acid leaching method was employed for the pre-treatment of marine sediments, while Fe(OH)3 co -precipitation was used for Am preconcentration in seawater samples. The extraction behaviors of Am on TK221 resins in the different acidic mediums were investigated. The removal capabilities of the tandem TK200-TK221 columns for the 241Am in the presence of interfering elements including Pu, Pb, Hg, Bi, Tl, Pt, Hf, U, and Th were carefully investigated and the corresponding decontamination factors (DFs) estimated to be in the range from 104 to 106. The main interfering element Pu was efficiently removed with a DF of about 6 x 105. Matrix rare earth elements (REEs) in marine sediments were further removed by the application of TEVA resins. 241Am mass fraction was quantified by the application of external calibration and SF ICP-MS. Following the recommendations of the ISO/IEC 17025 guidelines, the validation of the analytical procedure was accomplished by executing it on the certified reference material (CRM) IAEA-385 (marine sediment) and the seawater IAEA-443 reference materials (RM). The obtained results showed that 241Am mass fractions were accurately determined in both reference samples, with excellent reproducibility (2.1 % and 7.6 %) and low LODs (0.4 fg g-1 and 0.2 fg g-1). The relative expanded uncertainties (k = 2) obtained were 17.1 % and 29.0 %, respectively. The overall analytical times for the application of the proposed procedure on the marine sediment and seawater samples were evaluated to be only about 9 h and 6.5 h, respectively. It shows great advantages for its potential applications for emergency monitoring of 241Am contamination in the marine environment.
更多
查看译文
关键词
Americium-241,Marine sediment,Seawater,Extraction chromatography,SF ICP-MS,Method validation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要