A novel methodology for monitoring low-temperature corrosion caused by hygroscopic salts using linear polarization resistance

Sarah Yahi, Aicha Bensmaili,Juho Lehmusto,Leena Hupa,Ahmed Haddad, Manel Benmohamed,Emil Vainio

ELECTROCHIMICA ACTA(2024)

引用 0|浏览1
暂无评分
摘要
A new methodology for monitoring low-temperature corrosion caused by hygroscopic salts was developed and tested with ZnCl2. First, deliquescence and efflorescence points of ZnCl2 were determined by electrochemical impedance spectroscopy and chronoamperometry measurements in the range of 10-35 vol % H2O. Then, lowtemperature corrosion was monitored using a probe that combines linear polarization resistance and mass loss measurements. Suitable potential and scan rate for the linear polarization resistance measurements were experimentally determined. The feasibility of the probe was tested by monitoring the corrosiveness of ZnCl2 on P235GH steel under different temperatures (100-180 degrees C) and water vapor concentrations (15-35 vol %). With the developed corrosion probe, corrosion caused by hygroscopic salts during changes in testing conditions can be monitored and evaluated.
更多
查看译文
关键词
Hygroscopic salt,Corrosion monitoring,Linear polarization resistance,EIS,Chronoamperometry