Transceiver for Ultrasonic Intra-Body Area Networks With Non-Coherent BPSK Detection

IEEE Transactions on Circuits and Systems II: Express Briefs(2024)

引用 0|浏览1
暂无评分
摘要
This paper presents a transceiver for an Ultrasonic Intra-Body Area Network (UIBAN) enabling regular monitoring of low data rate bio-signals. The modulation scheme is Binary Phase Shift-Keying (BPSK) because of its superior energy efficiency compared to the other binary modulations. Therefore, a BPSK detector composed of a single D flip-flop is proposed. The carrier frequency is 1 MHz and the bit rate is 7.8125 kbits/s. The integrated circuit (IC) was designed in the 0.35 μm CMOS technology from AMS. The complete transceiver was measured with 2 2mm diameter ultrasound transducers. The measured Bit Error Rate (BER) was 1.8 × 10-3 and 1.3 × 10-2 over a distance of 3.1 cm and 17.5 cm in castor oil, although subjected to many reflections. This is, to the authors’ knowledge, the highest measured communication distance with two ultrasonic transducers of a volume lower than 10mm3 in an environment similar to that of the human body.
更多
查看译文
关键词
Implant,Piezoelectric transducer,Network