Treatment of atrial fibrillation with second-generation cryoballoon followed by contact-sensing radiofrequency catheter ablation for arrhythmia recurrences—results of a 5-year follow-up

Andrija Nekić,Ivan Prepolec,Vedran Pašara, Jakov Emanuel Bogdanić, Jurica Putrić Posavec, Domagoj Kardum, Zvonimir Katić, Andrija Štajduhar,Borka Pezo Nikolić,Davor Puljević,Davor Miličić, G. B. Chierchia,Carlo de Asmundis,Vedran Velagić

Journal of Interventional Cardiac Electrophysiology(2024)

引用 0|浏览1
暂无评分
摘要
Introduction The aim of this study was to report the long-term follow-up results of cryoballoon (CB) ablation in patients with atrial fibrillation. Methods All consecutive patients who underwent second-generation CB ablation from February 2015 to December 2017 were included in our study. In all procedures, we used a 28-mm CB placed via a single transseptal puncture guided by intracardiac ultrasound. A 20-mm octapolar intraluminal circular catheter was used for intracardiac recordings. A single 180-s freeze strategy was employed. Repeated procedures were performed with a 3D mapping system and radiofrequency catheters. Results A total of 126 patients (69.8% male, mean age 57 ± 11 years), of which 77.0% had paroxysmal atrial fibrillation (PAF), were included in the study. After a 5-year period, 52.4% of patients were in sinus rhythm without AF recurrence, off antiarrhythmic drugs. A total of 61.9% of patients were free of AF recurrence when redo PVI procedures were performed. When accounting for redo pulmonary vein isolation and antiarrhythmic drugs, a total of 73.8% of the patients were without AF recurrence in long-term follow-up. The patients who underwent redo pulmonary vein isolation procedures had statistically significant lower rates of AF recurrence ( p = 0.006). In patients with PAF, long-term success rates improved from 62.9 to 79.4% for patients who underwent the redo procedure ( p = 0.020). In patients with persistent atrial fibrillation (PersAF), success rates went up from 41.4 to 55.1% for patients with single or repeated PVI procedure ( p = 0.071). In the whole cohort, a total of 3 (2.4%) procedure-related major complications occurred which included persistent PNP, arterial pseudoaneurysm, and arteriovenous fistula. Conclusion Our data suggest a favorable long-term safety and efficacy profile of second-generation CB ablation. In the mixed paroxysmal and persistent population, up to 73.8% of patients remained free of AF recurrence in the 5-year follow-up, when accounting for redo procedures and AADs. Only 2.4% of patients experienced major complications of the ablation procedure, none with permanent sequelae. Graphical Abstract Central figure. K-M curves for overall population
更多
查看译文
关键词
Atrial fibrillation,Catheter ablation,Cryoballoon,Long-term follow-up
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要