Improvements to a GLCM-based machine-learning approach for quantifying posterior capsule opacification

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS(2024)

引用 0|浏览0
暂无评分
摘要
Background: Posterior capsular opacification (PCO) is a common complication following cataract surgery that leads to visual disturbances and decreased quality of vision. The aim of our study was to employ a machine-learning methodology to characterize and validate enhancements applied to the grey-level co-occurrence matrix (GLCM) while assessing its validity in comparison to clinical evaluations for evaluating PCO.Methods: One hundred patients diagnosed with age-related cataracts who were scheduled for phacoemulsification surgery were included in the study. Following mydriasis, anterior segment photographs were captured using a high-resolution photographic system. The GLCM was utilized as the feature extractor, and a supported vector machine as the regressor. Three variations, namely, GLCM, GLCM+C (+axial information), and GLCM+V (+regional voting), were analyzed. The reference value for regression was determined by averaging clinical scores obtained through subjective analysis. The relationships between the predicted PCO outcome scores and the ground truth were assessed using Pearson correlation analysis and a Bland-Altman plot, while agreement between them was assessed through the Bland-Altman plot.Results: Relative to the ground truth, the GLCM, GLCM+C, and GLCM+V methods exhibited correlation coefficients of 0.706, 0.768, and 0.829, respectively. The relationship between the PCO score predicted by the GLCM+V method and the ground truth was statistically significant (p < 0.001). Furthermore, the GLCM+V method demonstrated competitive performance comparable to that of two experienced clinicians (r = 0.825, 0.843) and superior to that of two junior clinicians (r = 0.786, 0.756). Notably, a high level of agreement was observed between predictions and the ground truth, without significant evidence of proportional bias (p > 0.05).Conclusions: Overall, our findings suggest that a machine-learning approach incorporating the GLCM, specifically the GLCM+V method, holds promise as an objective and reliable tool for assessing PCO progression. Further studies in larger patient cohorts are warranted to validate these findings and explore their potential clinical applications.
更多
查看译文
关键词
cataract surgery,grey level co-occurrence matrix,machine learning,posterior capsular opacification quantification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要