Detection of fibrosing interstitial lung disease-suspected chest radiographs using a deep learning-based computer-aided detection system: a retrospective, observational study.

Jumpei Ukita,Hirotaka Nishikiori,Kenichi Hirota,Seiwa Honda, Kiwamu Hatanaka, Ryoji Nakamura,Kimiyuki Ikeda,Yuki Mori,Yuichiro Asai,Hirofumi Chiba, Keisuke Ogaki

BMJ Open(2024)

引用 0|浏览0
暂无评分
摘要
OBJECTIVES:To investigate the effectiveness of BMAX, a deep learning-based computer-aided detection system for detecting fibrosing interstitial lung disease (ILD) on chest radiographs among non-expert and expert physicians in the real-world clinical setting. DESIGN:Retrospective, observational study. SETTING:This study used chest radiograph images consecutively taken in three medical facilities with various degrees of referral. Three expert ILD physicians interpreted each image and determined whether it was a fibrosing ILD-suspected image (fibrosing ILD positive) or not (fibrosing ILD negative). Interpreters, including non-experts and experts, classified each of 120 images extracted from the pooled data for the reading test into positive or negative for fibrosing ILD without and with the assistance of BMAX. PARTICIPANTS:Chest radiographs of patients aged 20 years or older with two or more visits that were taken during consecutive periods were accumulated. 1251 chest radiograph images were collected, from which 120 images (24 positive and 96 negative images) were randomly extracted for the reading test. The interpreters for the reading test were 20 non-expert physicians and 5 expert physicians (3 pulmonologists and 2 radiologists). PRIMARY AND SECONDARY OUTCOME MEASURES:The primary outcome was the comparison of area under the receiver-operating characteristic curve (ROC-AUC) for identifying fibrosing ILD-positive images by non-experts without versus with BMAX. The secondary outcome was the comparison of sensitivity, specificity and accuracy by non-experts and experts without versus with BMAX. RESULTS:The mean ROC-AUC of non-expert interpreters was 0.795 (95% CI; 0.765 to 0.825) without BMAX and 0.825 (95% CI; 0.799 to 0.850) with BMAX (p=0.005). After using BMAX, sensitivity was improved from 0.744 (95% CI; 0.697 to 0.791) to 0.802 (95% CI; 0.754 to 0.850) among non-experts (p=0.003), but not among experts (p=0.285). Specificity and accuracy were not changed after using BMAX among either non-expert or expert interpreters. CONCLUSION:BMAX was useful for detecting fibrosing ILD-suspected chest radiographs for non-expert physicians. TRIAL REGISTRATION NUMBER:jRCT1032220090.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要