The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: A Large Area Silicon Microcalorimeter for Background Particles Detection

M. D’Andrea, C. Macculi, S. Lotti, L. Piro, A. Argan, G. Minervini, G. Torrioli, F. Chiarello,L. Ferrari Barusso, E. Celasco, G. Gallucci, F. Gatti, D. Grosso, M. Rigano, D. Brienza, E. Cavazzuti, A. Volpe

Journal of Low Temperature Physics(2024)

引用 0|浏览0
暂无评分
摘要
We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm 2 silicon absorber sensed by a single 2 mm × 1 mm Ir/Au TES, featuring an on-chip heater for calibration and diagnostic purposes. We have illuminated the sample with 55 Fe (6 keV line) and 241 Am (60 keV line) radioactive sources, thus studying the detector response and the heater calibration accuracy at low energy. Furthermore, we have operated the sample in combination with a past-generation CryoAC prototype. Here, by analyzing the coincident detections between the two detectors, we have been able to characterize the background spectrum of the laboratory environment and disentangle the primary (i.e. cosmic muons) and secondaries (mostly secondary photons and electrons) signatures in the spectral shape.
更多
查看译文
关键词
ATHENA X-IFU,CryoAC,Anticoincidence,Cryogenics,Background