Does forearm referencing using a retroversion guide achieve the targeted retroversion of the humeral component in reverse shoulder arthroplasty?

Mohammad N. Jomaa, Marco Branni, Helen Ingoe, Roberto Pareyon,Kristine Italia,Marine Launay,Asma Salhi, Luke Gilliand, James Nielsen,Jashint Maharaj,Kenneth Cutbush,Ashish Gupta

Journal of Shoulder and Elbow Surgery(2023)

引用 0|浏览0
暂无评分
摘要
BACKGROUND:Component positioning affects clinical outcomes of reverse shoulder arthroplasty, which necessitates an implantation technique that is reproducible, consistent, and reliable. This study aims to assess the accuracy and precision of positioning the humeral component in planned retroversion using a forearm referencing guide. METHODS:Computed Tomography (CT) scans of 54 patients (27 males and 27 females) who underwent primary reverse shoulder arthroplasty for osteoarthritis or cuff tear arthropathy were evaluated. A standardized surgical technique was used to place the humeral stem in 15° of retroversion. Version was assessed intraoperatively visualizing the retroversion guide from above and referencing the forearm axis. Metal subtraction techniques from postoperative CT images allowed for the generation of 3D models of the humerus and for evaluation of the humeral component position. Anatomical humeral plane and implant planes were defined and the retroversion 3D angle between identified planes was recorded for each patient. Accuracy and precision were assessed. A subgroup analysis evaluated differences between male and female patients. RESULTS:The humeral retroversion angle ranged from 0.9° to 22.8°. The majority (81%) of the measurements were less than 15°. Mean retroversion angle (± SD) was 9.9° ± 5.8° (95% CI 8.4°-11.5°) with a mean percent error with respect to 15° of -34% ± 38 (95% CI -23, -44). In the male subgroup (n=27, range 3.8° to 22.5°), the mean retroversion angle was 11.9° ± 5.4° (95% CI 9.8°-14.1°) with a mean percent error with respect to 15° of -21% ± 36 (95% CI -6, -35). In the female subgroup (n=27, range 0.9° to 22.8°), mean retroversion angle was 8.0° ± 5.5° (95% CI 5.8°-10.1°) and the mean percent error with respect to 15° was -47% ± 36 (95% CI -32, -61). The differences between the two gender groups were statistically significant (p=0.006). CONCLUSION:Referencing the forearm using an extramedullary forearm referencing system to position the humeral stem in a desired retroversion is neither accurate nor precise. There is a non-negligible tendency to achieve a lower retroversion than planned, and the error is more marked in females.
更多
查看译文
关键词
Reverse Shoulder Arthroplasty,Humerus,Retroversion,Forearm-axis,Computer-generated 3D Models
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要