A simple conductivity measurement method using a peak-frequency feature of ferrite-cored eddy current sensor

NDT & E INTERNATIONAL(2024)

引用 0|浏览0
暂无评分
摘要
Eddy current sensing (ECS) is advantageous in metallic measurements, but the existing ECS-based conductivity measurement methods are limited in terms of complexity, accuracy, or measurement range. Based on a peakfrequency feature of sweep-frequency eddy current sensor, a conductivity measurement method for nonmagnetic plates is proposed. Deriving from the analytic solution of Dodd-Deeds, it is found that the peakfrequency, which is the peak frequency of the imaginary component of the induction spectrum change, is inversely proportional to the specimen's conductivity; the product of the conductivity and the peak-frequency is solely determined by a geometrical coupled parameter called spatial-frequency, which is independent of the conductivity of the specimen and is specified by the lift-off and the dimensions of sensor coils; the lift-off and the sensor coils dimensions have no impact on the inverse linearity between the conductivity and the peakfrequency, although produce different scales. The findings are also confirmed with finite element method (FEM) simulations and experimental results. Based on the findings, we propose to measure the conductivity using the inverse proportionality between the peak-frequency and the conductivity, and to eliminate the lift-off effect by calibrating the sensor with a known conductivity. In addition, we propose to use ferrite-cored sensor in experimental measurements, to improve the induction intensity in low frequency range in practical. The induction spectra characteristics of eddy current sensors with and without a ferrite core by FEM (finite element method) are compared, and the results show that the ferritecored eddy current sensor features the same peak-frequency as the air-cored eddy current sensor, but exhibits a stronger inductive impedance variation. Experiments were carried out on six samples with conductivities from 16.09 MS/m to 57.29 MS/m at different lift-offs. The relative conductivity measurement errors are within 1.26 % and the maximum absolute error is 0.43 MS/m. We analyze the measurement errors in terms of frequency resolution and lift-off, and propose methods for improvement. The conductivity measurement method based on the peak-frequency of ferrite-cored eddy current sensor shows its advantages in terms of simplicity, accuracy, immunity to the lift-off, and wide measuring range in non-magnetic metal plate conductivity measurements, because of the rarely mathematically approximation induced error and the determined inverse ratio between the conductivity and the peak-frequency.
更多
查看译文
关键词
Conductivity,Eddy current,Ferrite -cored,Peak -frequency,Lift-off
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要