Fine decoupling test and simulation study to maintain a large transverse emittance ratio in hadron storage rings

Y. Luo, I Blackler, M Blaskiewicz, W. Fischer, A. Marušić, C. Montag, T Shrey,Derong Xu

Journal of physics(2023)

引用 0|浏览3
暂无评分
摘要
Abstract In previous and existing hadron storage rings, the horizontal and vertical emittances are normally the same or very close. For the Hadron Storage Ring (HSR) of the Electron-Ion Collider (EIC), the design proton transverse emittance ratio is 10:1. To maintain this large emittance ratio, we need to have an online fine decoupling system to prevent transverse emittance exchange. For this purpose, we carried out fine decoupling experiments in the Relativistic Heavy Ion Collider (RHIC) and reviewed its previous operational data. Analytical prediction and numerical simulation are preformed to estimate how small the global coupling coefficient should be to maintain a 10:1 emittance ratio.
更多
查看译文
关键词
large transverse emittance ratio,hadron storage rings
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要