Electrode tissue coupling (ETC) influences lesion formation stronger than contact force

Europace(2023)

引用 0|浏览0
暂无评分
摘要
Funding Acknowledgements Type of funding sources: None. Background Several parameters are assumed to influence lesion size in RF ablation. Especially RF power, duration and contact force are considered for optimizing lesion quality and creating durable lesions. Recent data showed a significant influence of electrode-tissue-coupling (ETC) on lesion size and occurrence of steam pops. Therefore, this study aimed to investigate the impact of ETC and contact force on lesion progression in RF ablation. Methods RF-lesions were created using a contact force sensing catheter with the ability of measuring local impredance in an ex vivo porcine cardiac model. The experimental setup consisted of a saline-filled container, a dispersive electrode, a heated thermostat and a circulation pump to imitate in vivo conditions. Global impedance was kept at 120 Ohm as well as the temperature at 37°C. RF power of 20W, 30W, 40W, and 50W was used. The ETC levels (full/minor) and CF-level (1-5g, 10-15g and 20-25g) were systematically varied between minor and full coupling. In minor ETC-level, only the distal end of the catheter is in contact with the tissue. In full ETC-level, the whole catheter tip is in contact with the tissue. All parameters (power, temperature, global and local impedance, contact force, ETC, lesion size) were measured constantly during application of RF-current, enabling real-time correlation of RF parameters and lesion size. In case of an audible steam pop, RF application was stopped. Results 8654 measurements out of 72 lesions were included in analysis. Significant differences in lesion size were observed when ETC-level was differed. Lesion depth was significantly higher in full ETC-level (5.13 ± 0.99 mm vs. 9.45 ± 1.45 mm, p<0.001). No significant difference was seen in lesion diameter and depth by varying CF-level, when lesions were created in full ETC-level (Table 1). These findings are also illustrated in Figure 1. When lesions were analyzed in minor ETC-level only, significant differences were observed, when CF-levels were varied (Table 2). Conclusion ETC is a main predictor of lesion size in RF-ablation. CF also influences lesion depth and diameter. However, significant differences were only observed in minor ETC-levels. Consequently, CF might be a main factor for durable lesions in RF-ablation, but the influence of varied CF decreases when ETC-level is rising.
更多
查看译文
关键词
electrode tissue coupling,contact force,influences lesion formation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要