#3651 COMPARISON OF WHOLE-BODY VERSUS THORACIC BIOIMPEDANCE IN RELATION TO ULTRAFILTRATION VOLUME AND SYSTOLIC BLOOD PRESSURE DURING HEMODIALYSIS

Nephrology Dialysis Transplantation(2023)

引用 0|浏览1
暂无评分
摘要
Abstract Background and Aims In contrast to portable whole-body bioimpedance, which estimates fluid status at a single point in time, thoracic bioimpedance applied by a wearable device could enable continuous measurements. However, clinical experience with thoracic bioimpedance in patients in dialysis is still limited. The aim of this study is to test the reproducibility of whole-body and thoracic bioimpedance measurements and to compare their association with hemodynamic changes during hemodialysis. Method In total, 54 patients were included in this cross-sectional observational study. Whole-body resistance at 5kHz, thoracic resistance at 8kHz, systolic blood pressure and ultrafiltration volume were measured. All measurements were taken at pre- and end-dialysis during two consecutive sessions. Data were approached by mixed-modelling and Spearman correlation analysis. Results Intraclass correlation of pre- to end-dialysis changes in whole-body and thoracic resistance between the first and second session was .71 [.58 – .8] and .72 [.6 – .81] respectively (Fig. 1). The correlation between ultrafiltration volume and relative whole-body and thoracic resistance was respectively .94 [.91 ─ .96], p < .001 and .76 [.66 ─ .83], p < .001 in the first session and .95 [.93 ─ .97], p < .001 and .75 [.65 ─ .82], p < .001 in the second session (Table 1). Changes in systolic blood pressure negatively correlated to both bioimpedance techniques (whole-body resistance in the first session: -.37 [-.19 ─ -.53], p < .001; in the second session: -.37 [-.19 ─ -.53], p < .001; thoracic resistance in the first session -.45 [-.28 ─ -.59], p < .001; in the second session -.39 [-.22 ─ -.54], p < .001) (Table 1). Conclusion Bioimpedance signals from both devices were moderately reproducible between two dialysis sessions. Whereas the relation between changes in ultrafiltration volume and resistance was stronger for whole-body bioimpedance, the relation between changes in systolic blood pressure and resistance was at least comparable for thoracic measurements. Thoracic bioimpedance measurements by a wearable device may serve as an interesting alternative to whole-body measurements for continuous hemodynamic monitoring during hemodialysis.
更多
查看译文
关键词
hemodialysis,thoracic bioimpedance,ultrafiltration volume,blood pressure,systolic blood pressure,whole-body
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要