Applications of Near-Infrared Fluorescence Imaging and Angiography of Inferior Vesical Artery in Laparoscopic Lateral Lymph Node Dissection: A Prospective Nonrandomized Controlled Study

Diseases of The Colon & Rectum(2024)

引用 0|浏览3
暂无评分
摘要
BACKGROUND: Near-infrared imaging with indocyanine green has been used to guide lateral lymph node dissection, yet its efficacy and benefits need further investigation.OBJECTIVE: To investigate the efficacy and feasibility of near-infrared fluorescence imaging and angiography of the inferior vesical artery in laparoscopic lateral lymph node dissection.DESIGN: A prospective nonrandomized controlled study.SETTINGS: Single-center study.PATIENTS: Patients with lower rectal cancer who underwent total mesorectal excision plus lateral lymph node dissection.MAIN OUTCOME MEASURES: A cohort of 108 patients was enrolled. After propensity score matching, 29 patients in the near-infrared group and 50 patients in the non-near-infrared group were matched. The total number of harvested lateral lymph nodes, positive lateral lymph nodes, inferior vesical artery preservation, and postoperative urinary function were compared.RESULTS: After propensity score matching, both groups had similar baseline characteristics. The total number of harvested lateral lymph nodes in the near-infrared group was significantly higher (12 vs 9, p = 0.013), but positive lateral lymph nodes were similar between the 2 groups (1 vs 1, p = 0.439). The inferior vesical artery preservation ratio was significantly increased with the aid of indocyanine green angiography (93.1% vs 56.0%, p < 0.001). The non-near-infrared group required more days for urinary catheter removal than the near-infrared group (5 vs 4, p = 0.046). Urinary recatheterization tended to occur more frequently in the non-near-infrared group, with a marginally significant trend (16% vs 0%, p = 0.059). The non-near-infrared group tended to have more cases with residual urine volume >= 50 mL than the near-infrared group (20.0% vs 3.4%, p = 0.087), especially in the bilateral dissection subgroup (41.2% vs 0%, p = 0.041).LIMITATIONS: Small sample size.CONCLUSIONS: Near-infrared imaging increased the number of harvested lateral lymph nodes, whereas real-time indocyanine green fluorescence angiography ensured the preservation of the inferior vesical artery and tended to improve postoperative urinary function.
更多
查看译文
关键词
Indocyanine green,Inferior vesical artery,Lateral lymph node dissection,Near-infrared imaging,Rectal cancer,Urinary function
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要