Where to Draw Cerebrospinal Fluid from an External Ventricular Drain? Comparison of Cerebrospinal Fluid Parameters between Two Different Collection Sites

Diagnostics(2023)

引用 0|浏览9
暂无评分
摘要
Background: High cerebrospinal fluid (CSF) sampling frequency is considered a risk factor for external ventricular drain (EVD)-associated infections. To reduce manipulation at the proximal port and potentially minimize the risk of an infection, we aimed to analyze whether CSF parameters sampled from the far distal collection bag could provide reliable results compared to the proximal port. Methods: We included patients who were treated with an EVD at our neurosurgical intensive care unit (ICU) between June 2021 and September 2022. CSF sampling, including microbiological analysis, was performed simultaneously from the proximal port and the collection bag. Spearman's correlation coefficients were calculated to assess the correlation of CSF cell count, protein, lactate and glucose between the two sample sites. Results: We analyzed 290 pairs of CSF samples in 77 patients. Ventriculitis was identified in 4/77 (5%) patients. In 3/4 patients, microbiological analysis showed the same bacterial species at both sample sites at the same time. Spearman's correlation coefficient showed that CSF cell count (r = 0.762), lactate (r = 0.836) and protein (r = 0.724) had a high positive correlation between the two collection sites, while CSF glucose (r = 0.663) showed a moderate positive correlation. Conclusion: This study shows that biochemical CSF parameters can be reliably assessed from the EVD collection bag.