Fatigability of the thenar muscles using electrical nerve stimulation with fixed stimuli count, while varying the frequency and duty cycle

A. Gkesou, A. Papavasileiou, S. Karagiaridis,T. Kannas,I. G. Amiridis,V. Hatzitaki, D. A. Patikas

Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology(2023)

引用 0|浏览0
暂无评分
摘要
Our aim was to compare three electrical stimulation protocols (P20, P30 and P40), with the same number of stimuli, but different stimulation frequencies (20, 30 and 40 Hz, respectively) and duty cycles [1.2:1.2 s (continuous), 0.8:1.2 s (intermittent) and 0.6:1.2 s (intermittent), respectively). Twitch force and the peak-to peak M-wave amplitude of the thenar muscles were measured before, during and after each protocol at 1-40 Hz in random order. Twelve healthy adults (23-41 years old) were examined for each protocol in random order and in separate sessions. P20 elicited the highest mean force, and P40 the lowest decrease in percent force at the end of the protocol. Force evoked at 1 and 10 Hz decreased less after P40, compared with P20 and P30. The M wave amplitude was significantly reduced throughout all protocols, with the largest decrease observed during P30. Although an increase in frequency typically induced earlier and greater decrement in force, this was compensated or even reversed by increasing the interval between each stimulation train, while keeping the number of pulses per stimulation cycle constant. The lesser decrease in M-wave amplitude during P40 compared with P20 indicates that longer between-train intervals may help maintaining the integrity of neuromuscular propagation.
更多
查看译文
关键词
Fatigability,Electrical stimulation,M-wave,Median nerve,Thenar muscle,Low-frequency fatigue
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要