Magnetic anchor technique assisted endoscopic submucosal dissection for early esophageal cancer

World journal of gastrointestinal endoscopy(2023)

引用 0|浏览3
暂无评分
摘要
BACKGROUNDEsophageal cancer has high incidence globally and is often diagnosed at an advanced stage. With the widespread application of endoscopic technologies, the need for early detection and diagnosis of esophageal cancer has gradually been realized. Endoscopic submucosal dissection (ESD) has become the standard of care for managing early tumors of the esophagus, stomach, and colon. However, due to the steep learning curve, difficult operation, and technically demanding nature of the procedure, ESD has currently been committed to the development of various assistive technologies.AIMTo explore the feasibility and applicability of magnetic anchor technique (MAT)-assisted ESD for early esophageal cancer.METHODSIsolated pig esophagi were used as the experimental model, and the magnetic anchor device was designed by us. The esophagi used were divided into two groups, namely the operational and control groups, and 10 endoscopists completed the procedure. The two groups were evaluated for the following aspects: The total operative time, perforation rate, rate of whole mucosal resection, diameter of the peering mucosa, and scores of endoscopists' feelings with the procedure, including the convenience, mucosal surface exposure degree, and tissue tension. In addition, in the operational group, the soft tissue clip and the target magnet (TM) were connected by a thin wire through a small hole at the tail end of the TM. Under gastroscopic guidance, the soft tissue clip was clamped to the edge of the lesioned mucosa, which was marked in advance. By changing the position of the anchor magnet (AM) outside the esophagus, the pulling force and pulling direction of the TM could be changed, thus exposing the mucosal peeling surface and assisting the ESD.RESULTS Herein, each of the two groups comprised 10 isolated esophageal putative mucosal lesions. The diameter of the peering mucosa did not significantly differ between the two groups (2.13 +/- 0.06 vs 2.15 +/- 0.06, P = 0.882). The total operative time was shorter in the operational group than in the control group (17.04 +/- 0.22 min vs 21.94 +/- 0.23 min, P < 0.001). During the entire experiment, the TM remained firmly connected with the soft tissue clip and did not affect the opening, closing, and release of the soft tissue clip. The interaction between the TM and AM could provide sufficient tissue tension and completely expose the mucosa, which greatly assists the surgeon with the operation. There was no avulsion of the mucosa, and mucosal lesions were intact when peeled. Therefore, the scores of endoscopists' feelings were higher in the operational group than in the control group in terms of the convenience (9.22 +/- 0.19 vs 8.34 +/- 0.15, P = 0.002), mucosal surface exposure degree (9.11 +/- 0.15 vs 8.25 +/- 0.12, P < 0.001), and tissue tension (9.35 +/- 0.13 vs 8.02 +/- 0.17, P < 0.001). The two groups did not significantly differ in the perforation rate and rate of whole mucosal resection.CONCLUSIONWe found MAT-assisted ESD safe and feasible for early esophageal cancer. It could greatly improve the endoscopic operation experience and showed good clinical application prospects.
更多
查看译文
关键词
endoscopic submucosal dissection,magnetic anchor technique
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要