Intravascular ultrasonography assisted carotid artery stenting for treatment of carotid stenosis: Two case reports

Peng-Cheng Fu,Jing-Yi Wang, Ying Su, Yu-Qi Liao, Shao-Ling Li,Ge-Lin Xu, Yan-Jiao Huang, Ming-Hua Hu,Li-Ming Cao

World Journal of Clinical Cases(2023)

引用 0|浏览0
暂无评分
摘要
BACKGROUND Digital subtraction angiography (DSA), the gold standard of cerebrovascular disease diagnosis, is limited in its diagnostic ability to evaluate arterial diameter. Intravascular ultrasonography (IVUS) has advantages in assessing stenosis and plaque nature and improves the evaluation and effectiveness of carotid artery stenting (CAS). CASE SUMMARY Case 1: A 65-year-old man presented with a five-year history of bilateral lower limb weakness due to stroke. Physical examination showed decreased strength (5-/5) in both lower limbs. Carotid artery ultrasound, magnetic resonance angiography, and computed tomography angiography (CTA) showed a right proximal internal carotid artery (ICA) stenosis (70%-99%), acute cerebral infarction, and severe right ICA stenosis, respectively. We performed IVUS-assisted CAS to measure the stenosis and detected a low-risk plaque at the site of stenosis prior to stent implantation. Post-stent balloon dilatation was performed and postoperative IVUS demonstrated successful expansion and adherence. CTA six months postoperatively showed no significant increase in in-stent stenosis. Case 2: A 36-year-old man was admitted with a right common carotid artery (CCA) dissection detected by ultrasound. Physical examination showed no positive neurological signs. Carotid ultrasound and CTA showed lumen dilation in the proximal CCA with an intima-like structure and bulging in the proximal segment of the right CCA with strip-like low-density shadow (dissection or carotid web). IVUS-assisted DSA confirmed right CCA dissection. CAS was performed and intraoperative IVUS suggested a large residual false lumen. Post-stent balloon dilatation was performed reducing the false lumen. DSA three months postoperatively indicated good stent expansion with mild stenosis. CONCLUSION IVUS aids decision-making during CAS by accurately assessing carotid artery wall lesions and plaque nature preoperatively, dissection and stenosis morphology intraoperatively, and visualizing and confirming CAS postoperatively.
更多
查看译文
关键词
Intravascular ultrasonography,Carotid artery stenting,Carotid stenosis,Arteriosclerotic stenosis,Carotid artery dissection,Case report
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要