CFD-DEM investigation of the effects of aperture size for a capsule-based dry powder inhaler

INTERNATIONAL JOURNAL OF PHARMACEUTICS(2023)

引用 0|浏览3
暂无评分
摘要
Capsule based dry powder inhalers (DPIs) often require piercing of the capsule before inhalation, and the characteristics of the apertures (punctured holes) affect air flow and the release of powders from the capsule. This work develops a numerical model based on the two-way coupling of computational fluid dynamics and discrete element method (CFD-DEM) to investigate the effect of aperture size on powder dispersion in the Aerolizer (R) device loaded with only carrier particles (lactose). Powders (carrier particles) in the size range 60-140 mu m (d(50): 90 mu m and span: 0.66) were initialized in a capsule which had a circular aperture at each end. Boundary conditions corresponding to an air flow rate of 45 L/min were specified at each inlet to the mixing chamber (i.e., a total flow rate 90 L/min), and a capsule spin speed of similar to 4050 rpm. The velocity magnitudes inside the capsule were considerably lower than those in the mixing chamber in the vicinity of the rotating capsule, with the exception of the capsules featuring 2.5 mm and 4 mm apertures. Larger apertures reduced the capsule emptying time and increased the particle evacuation velocity; the fluid drag force on the particles issuing from the capsule peaked for an aperture of 1.3 mm. Inside the capsule, particle-particle (PP) collisions were more frequent than particle-wall (PW) collisions due to high concentration of powder, but PP collisions had smaller (median) impact energy than PW collisions. Larger apertures resulted in fewer collisions in the capsule with higher PW and virtually unchanged PP collision energies. Outside the capsule (i.e., in the inhaler mixing chamber), PW collisions occurred more frequently than PP collisions with median collision energies typically two orders of magnitude higher than inside the capsule. Larger apertures resulted in more collisions with slightly reduced collision energy, but this effect plateaued for aperture sizes larger than 1.3 mm. Powder dispersion, expressed as the fine particle fraction (FPF) of the powder, was predicted using an empirical equation based on carrier PW collisions. Therefore, consistent with the model prediction of the effect of aperture sizes on the chamber collision frequency, FPF increased with aperture size but plateaued beyond 1.3 mm.
更多
查看译文
关键词
Aerolizer,Dry powder inhaler (DPI),Capsule aperture,computational fluid dynamics (CFD),discrete element method (DEM)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要