Point-of-care testing for viral-associated pulmonary aspergillosis

EXPERT REVIEW OF MOLECULAR DIAGNOSTICS(2024)

引用 0|浏览0
暂无评分
摘要
IntroductionOver the last years, severe respiratory viral infections, particularly those caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the influenza virus, have emerged as risk factor for viral-associated pulmonary aspergillosis (VAPA) among critically ill patients. Delays in diagnosis of VAPA are associated with increased mortality. Point-of-care-tests may play an important role in earlier diagnosis of VAPA and thus improve patient outcomes.Areas coveredThe following review will give an update on point-of-care tests for VAPA, analyzing performances in respiratory and blood specimens.Expert opinionPoint-of-care tests have emerged, and particularly the IMMY Aspergillus galactomannan lateral flow assay (LFA) shows performances comparable to the galactomannan ELISA for diagnosis of VAPA. Notably, nearly all evaluations of POC tests for VAPA have been performed in COVID-19 patients, with very limited data in influenza patients. For early diagnosis of COVID associated pulmonary aspergillosis (CAPA), the LFA has shown promising performances in respiratory samples, particularly in bronchoalveolar lavage fluid, and may thereby help in improving patient outcomes. In contrast, serum LFA testing may not be useful for early diagnosis of disease, except in cases with invasive tracheobronchial aspergillosis.
更多
查看译文
关键词
Lateral flow device test,lateral flow assay,non-neutropenic,ICU,COVID,influenza,pulmonary aspergillosis,Aspergillus
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要