Marina Bikchurina,Timofey Bykov, Ibrahim Ibrahim, Ibrahim Ibrahim, Ibrahim Ibrahim,Anna Kasatova,Dmitrii Kasatov,Iaroslav Kolesnikov, Victoria Konovalova, Victoria Konovalova, Timur Kormushakov, Timur Kormushakov,Alexey Koshkarev,Alexey Koshkarev,Anton Kuznetsov,Anton Kuznetsov,Vyacheslav Porosev,Sergey Savinov,Ivan Shchudlo, Nataliia Singatulina, Nataliia Singatulina,Evgeniia Sokolova,Tatiana Sycheva,Iuliia Taskaeva,Gleb Verkhovod,Sergey Taskaev,Sergey Taskaev

Frontiers in Nuclear Engineering(2023)

引用 0|浏览0
暂无评分
摘要
The method of boron neutron capture therapy for malignant tumors, proposed in 1936, is beginning to enter clinical practice. The development of dosimetry tools for characterization of therapeutic mixed neutron-photon beam and assessing the patient’s response to treatment is becoming relevant. In this work, a number of dosimetric techniques have been developed: a compact neutron detector with a pair of cast scintillators, one of which is enriched with boron, to measure the boron dose and the γ-ray dose; cell dosimeter for measuring the sum of the equivalent dose of fast neutrons and the equivalent nitrogen dose; prompt γ-ray spectroscopy for in situ measurement of boron dose in real time; epithermal neutron flux monitor for measuring the epithermal neutron flux. Their verification carried out on the accelerator based neutron source VITA showed that they can become convenient and reliable tools for characterization of neutron beam and assessing the patient’s response to treatment.
更多
查看译文
关键词
boron neutron capture therapy,neutron source vita,accelerator
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要