High Mechanical Power and Driving Pressures are Associated With Postoperative Respiratory Failure Independent From Patients' Respiratory System Mechanics

CRITICAL CARE MEDICINE(2024)

引用 0|浏览5
暂无评分
摘要
OBJECTIVES: High mechanical power and driving pressure (Delta P) have been associated with postoperative respiratory failure (PRF) and may be important parameters guiding mechanical ventilation. However, it remains unclear whether high mechanical power and Delta P merely reflect patients with poor respiratory system mechanics at risk of PRF. We investigated the effect of mechanical power and Delta P on PRF in cohorts after exact matching by patients' baseline respiratory system compliance.DESIGN: Hospital registry study.SETTING: Academic hospital in New England.PATIENTS: Adult patients undergoing general anesthesia between 2008 and 2020.INTERVENTION: None.MEASUREMENTS AND MAIN RESULTS: The primary exposure was high (>= 6.7 J/min, cohort median) versus low mechanical power and the key-secondary exposure was high (>= 15.0 cm H2O) versus low Delta P. The primary endpoint was PRF (reintubation or unplanned noninvasive ventilation within seven days). Among 97,555 included patients, 4,030 (4.1%) developed PRF. In adjusted analyses, high intraoperative mechanical power and Delta P were associated with higher odds of PRF (adjusted odds ratio [aOR] 1.37 [95% CI, 1.25-1.50]; p < 0.001 and aOR 1.45 [95% CI, 1.31-1.60]; p < 0.001, respectively). There was large variability in applied ventilatory parameters, dependent on the anesthesia provider. This facilitated matching of 63,612 (mechanical power cohort) and 53,260 (Delta P cohort) patients, yielding identical baseline standardized respiratory system compliance (standardized difference [SDiff] = 0.00) with distinctly different mechanical power (9.4 [2.4] vs 4.9 [1.3] J/min; SDiff = -2.33) and Delta P (19.3 [4.1] vs 11.9 [2.1] cm H2O; SDiff = -2.27). After matching, high mechanical power and Delta P remained associated with higher risk of PRF (aOR 1.30 [95% CI, 1.17-1.45]; p < 0.001 and aOR 1.28 [95% CI, 1.12-1.46]; p < 0.001, respectively).CONCLUSIONS: High mechanical power and Delta P are associated with PRF independent of patient's baseline respiratory system compliance. Our findings support utilization of these parameters for titrating mechanical ventilation in the operating room and ICU.
更多
查看译文
关键词
anesthesia,general,lung compliance,New England,pulmonary ventilation,respiratory insufficiency,respiratory mechanics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要