Macular Perfusion Deficits on OCT Angiography Correlate with Nonperfusion on Ultrawide-field Fluorescein Angiography in Diabetic Retinopathy

OPHTHALMOLOGY RETINA(2023)

引用 2|浏览4
暂无评分
摘要
Objective: To evaluate the correlation between nonperfusion parameters on OCT angiography (OCTA) and ultrawide-field fluorescein angiography (UWF-FA) in subjects with diabetes mellitus (DM).Design: Prospective, cross-sectional study. Subjects: Subjects with DM and a wide range of diabetic retinopathy (DR) severity seen at a tertiary referral center.Methods: We used averaged 3 x 3 mm OCTA scans to measure geometric perfusion deficit (GPD), vessel density, and vessel length density in the full retina, superficial capillary plexuses (SCPs), and deep capillary plexuses (DCPs). Nonperfusion was manually delineated on UWF-FA to quantify central, peripheral, and total retinal nonperfusion (mm2 and % area).Main Outcome Measures: Correlation between OCTA parameters and UWF-FA nonperfusion, and accuracy of these OCTA and UWF-FA parameters in detecting clinically referable eyes, using receiver operating charac-teristic (ROC) curve analysis, sensitivity, specificity, and area under the ROC curve (AUC).Results: The study included 67 eyes (12 eyes with no signs of DR, 8 mild, 22 moderate, 14 severe non-proliferative DR, and 11 treatment-naive proliferative DR). There was a fair-to-moderate correlation between either central or total retinal nonperfusion on UWF-FA (mm2) and GPD in the SCP (r = 0.482 and r = 0.464, respectively) and DCP (r = 0.470 and r = 0.456, respectively). Receiver operating characteristic analysis showed the DCP GPD significantly superior to other OCTA parameters at the DCP with the largest overall AUC on OCTA for dis-tinguishing referable DR (0.905). Furthermore, the GPD parameter had the largest AUC in each respective capillary layer compared with other parameters. Overall, the total UWF-FA nonperfusion area showed a com-parable AUC (0.907) and performed significantly better than peripheral nonperfusion (P = 0.041). Comparing the AUC values between GPD and UWF-FA nonperfusion parameters showed no significant difference in discerning referable DR.Conclusions: Nonperfusion as quantified on OCTA (3 x 3 mm) correlated with UWF-FA parameters and both were comparable in detecting referable DR. These macular OCTA metrics, particularly DCP GPD, have the potential for gauging the overall ischemic status of the retina, with an important clinical role in identifying eyes with clinically referable DR.Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology Retina 2023;7:692-702 & COPY; 2023 by the American Academy of Ophthalmology
更多
查看译文
关键词
Diabetic retinopathy,Fluorescein angiography,Retinal nonperfusion,Retina,OCT angiography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要