An Immunologic and Biomechanical Comparison of Polyether Ether Ketone-Zeolite and Polyether Ether Ketone Interbody Fusion Devices

SPINE(2023)

引用 0|浏览8
暂无评分
摘要
Study Design.A laboratory study comparing polyether ether ketone (PEEK)-zeolite and PEEK spinal implants in an ovine model. Objective.This study challenges a conventional spinal implant material, PEEK, to PEEK-zeolite using a nonplated cervical ovine model. Summary of Background Data.Although widely used for spinal implants due to its material properties, PEEK is hydrophobic, resulting in poor osseointegration, and elicits a mild nonspecific foreign body response. Zeolites are negatively charged aluminosilicate materials that are hypothesized to reduce this pro-inflammatory response when used as a compounding material with PEEK. Materials and Methods.Fourteen skeletally mature sheep were, each, implanted with one PEEK-zeolite interbody device and one PEEK interbody device. Both devices were packed with autograft and allograft material and randomly assigned to one of 2 cervical disc levels. The study involved 2 survival time points (12 and 26 weeks) and biomechanical, radiographic, and immunologic endpoints. One sheep expired from complications not related to the device or procedure. A biomechanical evaluation was based on measures of segmental flexibility, using 6 degrees of freedom pneumatic spine tester. Radiographic evaluation was performed using microcomputed tomography scans in a blinded manner by 3 physicians. Levels of the pro-inflammatory cytokines, interleukin (IL)-1 & beta;, IL-6, and tumor necrosis factor-alpha at the implant, were quantified using immunohistochemistry. Results.PEEK-zeolite and PEEK exhibited an equivalent range of motion in flexion extension, lateral bending, and axial torsion. A motion was significantly reduced for implanted devices at both time points as compared with native segments. Radiographic assessments of fusion and bone formation were similar for both devices. PEEK-zeolite exhibited lower levels of IL-1 & beta; (P = 0.0003) and IL-6 (P = 0.03). Conclusion.PEEK-zeolite interbody fusion devices provide initial fixation substantially equivalent to PEEK implants but exhibit a reduced pro-inflammatory response. PEEK-zeolite devices may reduce the chronic inflammation and fibrosis previously observed with PEEK devices.
更多
查看译文
关键词
biomechanics, cervical ovine model, cytokines, fusion, inflammation, interbody devices, microCT, PEEK, PEEK-zeolite, range of motion
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要