Primary Stability and Bone Contact Loading Evaluation of Suture and Screw based Coracoid Graft Fixation for Anterior Glenoid Bone Loss

The American journal of sports medicine(2023)

引用 0|浏览0
暂无评分
摘要
Background: Reconstruction techniques for anterior glenoid bone loss have seen a trend from screws to suture-based fixations. However, comparative biomechanical data, including primary fixation and glenoid-graft contact pressure mapping, are limited. Hypothesis: Suture-based bone block cerclage (BBC) and suspensory suture button (SB) techniques provide similar primary fixation and cyclic stability to double-screw fixation but with higher contact loading at the bony interface. Study Design: Controlled laboratory study. Methods: In total, 60 cadaveric scapulae were prepared to simulate anterior glenoid bone loss with coracoid autograft reconstruction. Graft fixation was performed with 3 different techniques: (1) an interconnected all-suture BBC, (2) 2 SB suspensions, and (3) 2 screws. Initial compression was analyzed during primary fixation. Cyclic peak loading with 50 N and 100 N over 250 cycles at 1 Hz was performed with a constant valley load of 25 N. Optical recording and pressure foils allowed for spatial bone block tracking and contact pressure mapping at the glenoid-graft interface. Load-to-failure testing was performed at a rate of 1.5 mm/s with ultimate load and stiffness measured. Results: Initial graft compression was higher with screw fixation (141 6 5 N) compared with suture-based fixations (P\.001), with BBC fixation providing significantly higher compression than SB fixation (116 6 7 N vs. 91 6 5 N; P \.001). Spatial bone block migration and ultimate failure load were similar between the BBC and screw groups. The SB group showed significantly increased bone block translation (3.1 6 1.0 mm; P similar to.014) and rotation (2.5 similar to 6 1.4 similar to; P similar to.025) and significantly lower ultimate failure load (180 6 53 N) compared with the BBC (P =.046) and screw (P =.002) groups. Both suture-based fixations provided significantly increased graft-glenoid contact loading with higher pressure amplitudes (P similar to.032) and contact pressure after cyclic loading ( 113%; SB: P =.007; BBC: P =.004) compared with screw fixation. Conclusion: Both SB and interconnected cerclage fixation improved dynamic contact loading compared with screw fixation in a biomechanical glenoid bone loss model. Cerclage fixation was biomechanically comparable with screw fixation but with a greater variability. SB fixation showed significantly lower primary fixation strength and greater bone block rotation and migration. Clinical Relevance: Suture-based bone block fixations improved graft-glenoid contact loading, but the overall clinical consequence on healing remains unclear.
更多
查看译文
关键词
glenoid bone loss,coracoid fixation,suture-based fixation,cerclage,contact pressure,biomechanics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要