Reducing the Measurement Time in a Reverberation Chamber to Less than 1 Second

APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL(2023)

引用 0|浏览2
暂无评分
摘要
- To increase the speed of the measurement, a time-efficient multi-probe system in a reverberation chamber (RC) is validated. The system consists of 4 printed circuit board (PCB) switches integrating with 128 probe antennas. By using solid-state switches, all antennas can be switched over in sequence in less than 1 second. Typical characteristics of the RC and the total radiated power (TRP) of the device under test (DUT) are performed to verify the validity of this configuration. Compared with the RC using mechanical stirrers, this system shows its superiority in terms of testing efficiency.