Pd33-10 non-invasive optical determination of detrusor pressure related to detrusor overactivity

The Journal of Urology(2023)

引用 0|浏览2
暂无评分
摘要
You have accessJournal of UrologyCME1 Apr 2023PD33-10 NON-INVASIVE OPTICAL DETERMINATION OF DETRUSOR PRESSURE RELATED TO DETRUSOR OVERACTIVITY Lynn Stothers, Andrew Macnab, Naser Hakimi, W. N. J. M. Colier, P. Pourabbassi, and M. Maresse Lynn StothersLynn Stothers More articles by this author , Andrew MacnabAndrew Macnab More articles by this author , Naser HakimiNaser Hakimi More articles by this author , W. N. J. M. ColierW. N. J. M. Colier More articles by this author , P. PourabbassiP. Pourabbassi More articles by this author , and M. MaresseM. Maresse More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003326.10AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Gold standard urodynamic studies use invasive methods and artificial filling of the bladder to determine detrusor pressure, a critical physiologic measure in determining care for lower urinary tract symptoms (LUTS). The benefits of non-invasive measurement of detrusor pressure (Pdet) include natural filling observations & the potential for a homebased wearable with real time data to determine both self-care and monitoring. Aim: to develop a wearable optical based technology to relate non-invasively measured changes in Pdet during natural filling. METHODS: A 10 x 10 cm optical grid using light emitting diodes (LED’s) (750 nm – 950 nm) was engineered & positioned suprapubically during simultaneous multichannel urodynamics (UDS). LED’s were paired with photodetectors, sampling at 50Hz from long (deep) and short (superficial) channels facilitating optical output compared to variations in Pdet. Output: Arterial pulse waveform changes in chromophore concentration related to variations in detrusor oxygenation (O2Hb), & fluctuations in the absorption of photons at 950nm (H20) related to CMG volume increases. Peak & trough envelopes were computed with Hilbert transformation and a filtered moving average was used mathematically. RESULTS: N=25 (5 controls no LUTS & 20 NLUTD female=N=5 age 64-82 yrs ASIA A, B & D; male=N=15 age 33 – 79 yrs being ASIA A,B,C & D. NLUTD management included: N=4 subjects using clean intermittent catheterization (CIC), 2 condom drainage, 5 using combinations of CIC and spontaneous voiding, 4 spontaneous voiding only. No subjects used anticholinergics, B 3 agonists or prior intra detrusor botulinum toxin. Controls: natural filling and uroflow, no LUTS on IPSS or UGDI, no prior GU surgery, volumes >150cc, repeated filling & emptying for internal consistency measures. CONCLUSIONS: A prototype wearable able to derive a real-time, non-invasive measure reflecting detrusor pressure was successfully prototyped. If further research confirms the ability of an optical parameter derived in this way to mirror variations in detrusor pressure, benefits that would accrue include: more frequent assessment than is possible with invasive UDS, & the ability to monitor changes in pressure continuously in an at risk population (e.g. NLUTD at risk for autonomic dysreflexia). Source of Funding: Craig H Neilsen Foundation © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e917 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Lynn Stothers More articles by this author Andrew Macnab More articles by this author Naser Hakimi More articles by this author W. N. J. M. Colier More articles by this author P. Pourabbassi More articles by this author M. Maresse More articles by this author Expand All Advertisement PDF downloadLoading ...
更多
查看译文
关键词
detrusor pressure,optical,non-invasive
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要