Improved performance of non-preloaded and high flip-angle dynamic susceptibility contrast perfusion-weighted imaging sequences in the presurgical differentiation of brain lymphoma and glioblastoma

Feng Wang,Xiaofang Zhou, Ruiquan Chen,Jie Kang,Xinyi Yang, Jinzhu Lin, Fang Liu,Dairong Cao,Zhen Xing

European radiology(2023)

引用 0|浏览7
暂无评分
摘要
Objective This study aimed to compare the accuracy of relative cerebral blood volume (rCBV) and percentage signal recovery (PSR) obtained from high flip-angle dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) sequences with and without contrast agent (CA) preload for presurgical discrimination of brain glioblastoma and lymphoma. Methods Consecutive 336 patients (glioblastoma, 236; PCNSL, 100) were included. All the patients underwent DSC-PWI on 3.0-T magnetic resonance units before surgery. The rCBV and PSR with preloaded and non-preloaded CA were measured. The means of the continuous variables were compared using Welch’s t-test. The diagnostic accuracies of the individual parameters were compared using the receiver operating characteristic curve analysis. Results The rCBV was higher with preloaded CA than with non-preloaded CA (glioblastoma, 10.20 vs. 8.90, p = 0.020; PCNSL, 3.88 vs. 3.27, p = 0.020). The PSR was lower with preloaded CA than with non-preloaded CA (glioblastoma, 0.59 vs. 0.90; PCNSL, 0.70 vs. 1.63; all p < 0.001). Regarding the differentiation of glioblastoma and PCNSL, the AUC of rCBV with preloaded CA was indistinguishable from that of non-preloaded CA (0.940 vs. 0.949, p = 0.703), whereas the area under the curve of PSR with preloaded CA was lower than non-preloaded CA (0.529 vs. 0.884, p < 0.001). Conclusion With preloaded CA, diagnostic performance in differentiating glioblastoma and PCNSL did not improve for rCBV and it was decreased for PSR. Therefore, high flip-angle non-preload DSC-PWI sequences offer excellent accuracy and may be of choice sequence for presurgical discrimination of brain lymphoma and glioblastoma. Clinical relevance statement High flip-angle DSC-PWI using non-preloaded CA may be an excellent diagnostic method for distinguishing glioblastoma from PCNSL. Key Points • Differentiating primary central nervous system lymphoma and glioblastoma accurately is critical for their management. • DSC-PWI sequences optimised for the most accurate CBV calculations may not be the optimal sequences for presurgical brain tumour diagnosis as they could be masquerading leakage phenomena that may provide interesting information in terms of differential diagnosis. • High flip-angle non-preloaded DSC-PWI sequences render the best accuracy in the presurgical differentiation of brain lymphoma and glioblastoma.
更多
查看译文
关键词
brain lymphoma,glioblastoma,imaging sequences,non-preloaded,flip-angle,perfusion-weighted
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要