Risk Factors for Graft Failure After Meniscal Allograft Transplantation: A Systematic Review and Meta-analysis.

Orthopaedic journal of sports medicine(2023)

引用 2|浏览0
暂无评分
摘要
Background:Graft failure after meniscal allograft transplantation (MAT) may necessitate revision surgery or conversion to arthroplasty. A comprehensive understanding of the risk factors for failure after MAT of the knee may facilitate more informed shared decision-making discussions before surgery and help determine whether MAT should be performed based on patient risk. Purpose:To perform a systematic review and meta-analysis of risk factors associated with graft failure after MAT of the knee. Study Design:Systematic review; Level of evidence, 4. Methods:The PubMed, OVID/Medline, and Cochrane databases were queried in October 2021. Data pertaining to study characteristics and risk factors associated with failure after MAT were recorded. DerSimonian-Laird binary random-effects models were constructed to quantitatively evaluate the association between risk factors and MAT graft failure by generating effect estimates in the form of odds ratios (ORs) with 95% CIs. Qualitative analysis was performed to describe risk factors that were variably reported. Results:In total, 17 studies including 2184 patients were included. The overall pooled prevalence of failure at the latest follow-up was 17.8% (range, 3.3%-81.0%). In 10 studies reporting 5-year failure rates, the pooled prevalence of failure was 10.9% (range, 4.7%-23%). In 4 studies reporting 10-year failure rates, the pooled prevalence was 22.7% (range, 8.1%-55.0%). A total of 39 risk factors were identified, although raw data presented in a manner amenable to meta-analysis only allowed for 3 to be explored quantitatively. There was strong evidence to support that an International Cartilage Regeneration & Joint Preservation Society grade >3a (OR, 5.32; 95% CI, 2.75-10.31; P < .001) was a significant risk factor for failure after MAT. There was no statistically significant evidence to incontrovertibly support that patient sex (OR, 2.16; 95% CI, 0.83-5.64; P = .12) or MAT laterality (OR, 1.11; 95% CI, 0.38-3.28; P = .85) was associated with increased risk of failure after MAT. Conclusion:Based on the studies reviewed, there was strong evidence to suggest that degree of cartilage damage at the time of MAT is associated with graft failure; however, the evidence was inconclusive on whether laterality or patient sex is associated with graft failure.
更多
查看译文
关键词
meniscal allograft transplantation,graft failure,systematic review,meta-analysis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要