Heavy concrete shielding properties for carbon therapy

Jin-Long Wang, Jiade J. Lu,Da -Jun Ding,Wen-Hua Jiang, Ya-Dong Li,Rui Qiu,Hui Zhang, Xiao-Zhong Wang, Huo-Sheng Ruan, Yan-Bing Teng,Xiao-Guang Wu,Yun Zheng,Zi-Hao Zhao, Kai-Zhong Liao, Huan-Cheng Mai, Xiao-Dong Wang, Ke Peng, Wei Wang, Zhan Tang, Zhao-Yan Yu,Zhen Wu, Hong -Hu Song, Shuo-Yang Wei, Sen-Lin Mao, Jun Xu, Jing Tao, Min-Qiang Zhang, Xi-Qiang Xue, Ming Wang

Nuclear Engineering and Technology(2023)

引用 2|浏览5
暂无评分
摘要
As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material compo-sition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 mSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation. (c) 2023 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
更多
查看译文
关键词
Carbon therapy,Heavy concrete,Magnetite,Radiation shielding,Monte Carlo,FLUKA
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要