Evaluation of neutron dose rates at the TCV tokamak facility

M. Fortuna, P. Blanchard,A. Čufar, M. Vallar, H. Weisen,A. Žohar,L. Snoj

Fusion Engineering and Design(2023)

引用 1|浏览4
暂无评分
摘要
•TCV fusion tokamak upgrade prompted Monte Carlo simulations of radiation doses.•ADVANTG code used for weight window generation.•Modelling of systems structures and components important for neutron field calculation.•Resulting polyethylene shield provide sufficient neutron protection at full power operation.
更多
查看译文
关键词
MCNP, Neutron transport, Shielding TCV, Experimental validation, Dose rate, Neutron
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要