Initial experience with a modified "candy-plug" technique for false lumen embolization in chronic type B aortic dissection

Journal of Vascular Surgery Cases, Innovations and Techniques(2023)

引用 2|浏览7
暂无评分
摘要
Background: Persistent distal false lumen (FL) perfusion after thoracic endovascular aortic repair (TEVAR) for type B aortic dissection (TBAD) can lead to aneurysmal degeneration and an increased risk of rupture. We have presented our initial experience using a modified "candy-plug" (CP) technique for FL embolization. Methods: From February 2021 to July 2022, we treated six patients using the modified CP technique. All the patients had undergone prior or simultaneous TEVAR for chronic TBAD with persistent FL perfusion and aneurysm expansion. Bilateral common femoral artery access was obtained, and intravascular ultrasound was used to confirm wire access in the true lumen (TL) and FL. A conformable TAG device (W.L. Gore & Associates, Flagstaff, AZ) was used in four cases and an Excluder aortic cuff (W.L. Gore & Associates) in two cases. The device was modified by placing a constraining "napkin-ring" suture through the middle segment of the device. Femoral sheaths were placed in the TL and FL. A standard TL TEVAR extension was performed at the level of the celiac artery (zone 5). Next, the CP device was advanced and deployed in the FL, distally aligning it with the TL device. An appropriately sized Amplatzer II plug (Abbot Vascular, Santa Clara, CA) was then deployed in the constrained segment of the modified stent graft. Completion angiography was performed to confirm successful FL embolization. Results: Technical success was defined as successful deployment of the CP device in the FL. The technical success rate was 100% (six of six patients). Clinical success was defined as the cessation of aneurysm growth on follow-up computed tomography angiography. No 30-day mortality, myocardial infarction, stroke, spinal cord ischemia, access site compli-cations, or aortic-related reinterventions occurred. Surveillance imaging at a mean follow-up of 10 months confirmed clinical success (stable aneurysm size or shrinkage) for all five patients with follow-up data available. Conclusions: The modified CP embolization technique is a promising solution for persistent distal FL perfusion after TEVAR for TBAD. Further investigation is required to determine the long-term durability of this technique as an adjunct to TEVAR to promote aortic remodeling. (J Vasc Surg Cases Innov Tech 2023
更多
查看译文
关键词
Aortic remodeling,Candy-plug,False lumen embolization,False lumen perfusion,TEVAR,Type B aortic dissection
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要