Estimated GFR Accuracy When Cystatin C- and Creatinine-Based Estimates Are Discrepant in Older Adults

KIDNEY MEDICINE(2023)

引用 2|浏览3
暂无评分
摘要
Rationale & Objective: Serum creatinine and cystatin C are used to estimate glomerular filtration rate, but creatinine-based estimated glomerular filtration rate (eGFRcr), cystatin C-based estimated glomerular filtration rate (eGFRcys), and combined creatinine-and cystatin C-based estimated glomerular filtration rate (eGFRcr-cys) are often divergent, particularly in older adults. We investigated which estimated glomerular filtration rate (eGFR) was more accurate and less biased compared with measured glomerular filtration rate (mGFR).Study Design: A diagnostic test study from the Berlin Initiative Study. Setting & Participants: The study population included 657 individuals aged 70 years or older with iohexol plasma clearance (mGFR) and serum creatinine and cystatin C measurements: 567 community-dwelling participants and 90 with a serum creatinine of >= 1.5 mg/dL. Tests Compared: We defined 3 groups on the basis of the difference eGFRcys - eGFRcr: whether < -5 mL/min/1.73 m2 (lower eGFRcys), within 5 mL/min/1.73 m2 (reference), or >= 5 mL/ min/1.73 m2 (lower eGFRcr). eGFRcr, eGFRcys, and eGFRcr-cys were compared to mGFR to assess bias and accuracy.Outcome: Median bias (eGFR minus mGFR) with 95% CIs and accuracy (percentage of eGFR values within +/- 30% of mGFR).Results: The mean +/- standard deviation age was 78 +/- 6 years; the mean eGFRcys, eGFRcr, and eGFRcr-cys were 59 +/- 23, 64 +/- 20, and 61 +/- 22 mL/ min/1.73 m2, respectively, and the mean mGFR was 56 +/- 19 mL/min. Half of the participants were in the lower eGFRcys group (n=337, 51%). Among them, the median bias for eGFRcys was the lowest (median bias, -2.7; 95% CI, -3.8 to -1.9) compared with the other eGFR equations. Conversely, in the lower eGFRcr group (n=121, 18%), the median bias for eGFRcr was the lowest compared with those for eGFRcys and eGFRcr-cys (2.9; [95% CI, 0.9-4.8] vs 13.8 [95% CI, 11.4-15.6] and 9.5 [95% CI, 7.7-11.0], respectively). Accuracy (percentage of eGFR values within +/- 30% of mGFR) was 93% for eGFRcr in the lower eGFRcr group and 92% for eGFRcys and 94% for eGFRcr-cys in the lower eGFRcys group.Limitations: Untested generalizability in younger populations. Conclusions: Among older adults, the lower eGFR between eGFRcys and eGFRcr was a more ac-curate and less biased estimate of mGFR when comparing the groups.
更多
查看译文
关键词
gfr accuracy,creatinine-based
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要