Optimal design of iron-cored coil sensor in magnetic flux leakage detection of thick-walled steel pipe

MEASUREMENT SCIENCE AND TECHNOLOGY(2023)

引用 1|浏览0
暂无评分
摘要
Thick-walled steel pipes, which bear high internal pressure, are widely applied in nuclear power and pressure pipelines. If there are defects in the inner wall, they are easy to expand and cause accidents. Therefore, the thick-walled steel pipe must be subject to non-destructive testing after production. For the magnetic flux leakage (MFL) testing method, the detection sensitivity gradually decreases with the increase of wall thickness. To solve this problem, a new structure of MFL probe is proposed in this paper. The influence of the iron core permeability on the MFL signal is analyzed theoretically, and the effect of the core length and diameter on the MFL signal is analyzed by simulation. The variation of the MFL signal with the change of the iron core and coil lift-off is studied respectively. The simulation results are verified by experiments. It is found that the lift-off of the iron-cored coil is determined by the iron core position. Based on this phenomenon, an MFL array probe is designed, which can be used for online detection of thick-walled steel pipes to improve the detection sensitivity of inner wall defects.
更多
查看译文
关键词
magnetic flux leakage detection,coil sensor,iron-cored,thick-walled