Intracardiac Echocardiography Guidance for Left Bundle Pacing: An Expensive Adjunct or Necessity for Optimal Lead Placement?

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY(2023)

引用 0|浏览1
暂无评分
摘要
HomeCirculation: Arrhythmia and ElectrophysiologyVol. 16, No. 4Intracardiac Echocardiography Guidance for Left Bundle Pacing: An Expensive Adjunct or Necessity for Optimal Lead Placement? No AccessEditorialRequest AccessFull TextAboutView Full TextView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toNo AccessEditorialRequest AccessFull TextIntracardiac Echocardiography Guidance for Left Bundle Pacing: An Expensive Adjunct or Necessity for Optimal Lead Placement? Syeda Atiqa Batul and Pugazhendhi Vijayaraman Syeda Atiqa BatulSyeda Atiqa Batul https://orcid.org/0000-0002-7970-710X Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, PA. Search for more papers by this author and Pugazhendhi VijayaramanPugazhendhi Vijayaraman Correspondence to: Pugazhendhi Vijayaraman, MD, Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, 1000 E Mountain Blvd, MC 36-10, Wilkes-Barre, PA 18711. Email E-mail Address: [email protected] https://orcid.org/0000-0003-2230-100X Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, PA. Search for more papers by this author Originally published23 Mar 2023https://doi.org/10.1161/CIRCEP.123.011931Circulation: Arrhythmia and Electrophysiology. 2023;16This article is a commentary on the followingIntracardiac Echocardiography–Guided Implantation for Proximal Left Bundle Branch PacingFootnotesFor Disclosures, see page 224.The opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.Correspondence to: Pugazhendhi Vijayaraman, MD, Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, 1000 E Mountain Blvd, MC 36-10, Wilkes-Barre, PA 18711. Email [email protected].eduReferences1. Vijayaraman P, Chung M, Dandamudi G, Upadhyay G, Krishnan K, Crossley G, Campbell K, Lee B, Refaat M, Saksena S, et al. His bundle pacing.JACC. 2018; 72:927–947. doi: 10.1016/j.jacc.2018.06.017CrossrefMedlineGoogle Scholar2. Huang W, Chen X, Su L, Wu S, Xia X, Vijayaraman P. A beginner’s guide to left bundle branch pacing.Heart Rhythm. 2019; 16:1791–1796. doi: 10.1016/j.hrthm.2019.06.016CrossrefMedlineGoogle Scholar3. Zhang J, Wang Z, Zu L, Cheng L, Su R, Wang X, Liang Z, Chen J, Hang F, Du J, et al. Simplifying physiological left bundle branch area pacing using a new nine-partition method.Can J Cardiol. 2021; 37:329–338. doi: 10.1016/j.cjca.2020.05.011CrossrefMedlineGoogle Scholar4. Upadhyay G, Cherian T, Shatz D, Beaser A, Aziz Z, Ozcan C, Broman M, Nayak H, Tung R. Intracardiac delineation of septal conduction in left bundle-branch block patterns. Mechanistic evidence of left intrahisian block circumvented by His pacing.Circulation. 2019; 139:1876–1888. doi: 10.1161/CIRCULATIONAHA.118.038648LinkGoogle Scholar5. Karki R, Raina A, Ezzeddine F, Bois M, Asirvatham S. Anatomy and pathology of the cardiac conduction system.Card Electrophysiol Clin. 2021; 13:569–584. doi: 10.1016/j.ccep.2021.06.003CrossrefMedlineGoogle Scholar6. Long D, Dong J, Sang C, Jiang CX, Tang R, Yan Q, Yu R, Li S, Yao Y, Ning M, et al. Isolated conduction within the left His-Purkinje system during sinus rhythm and idiopathic left ventricle tachycardia: findings from mapping the whole conduction system.Circ Arrhythm Electrophysiol. 2013; 6:522–527. doi: 10.1161/CIRCEP.113.000293LinkGoogle Scholar7. Mafi-Rad M, Luermans JG, Blaauw Y, Janssen M, Crijns HJ, Prinzen FW, Vernooy K. Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum.Circ Arrhythm Electrophysiol. 2016; 9:e003344. doi: 10.1161/CIRCEP.115.003344LinkGoogle Scholar8. Vijayaraman P, Panikkath R, Mascarenhas V, Bauch TD. Left bundle branch pacing utilizing three dimensional mapping.J Cardiovasc Electrophysiol. 2019; 30:3050–3056. doi: 10.1111/jce.14242CrossrefMedlineGoogle Scholar9. Vijayaraman P, Panikkath R. Intracardiac echocardiography-guided left bundle branch pacing in a patient with tricuspid valve replacement.J Cardiovasc Electrophysiol. 2019; 30:2525–2527. doi: 10.1111/jce.14205CrossrefMedlineGoogle Scholar10. Kuang X, Zhang X, Gao X, Wang L, Ding L, Zhang J, Xiang H, Guo J, Gao T, Wei F, et al. Intracardiac echocardiography-guided left bundle branch pacing.Int J Heart Rhythm. 2019; 4:20–25CrossrefGoogle Scholar11. Kuang XH, Zhang X, Cui YJ, Wei FY, Wu P, Gao XL, Xiang H, Wu HY, Wang LL, Zhou X, et al. Intracardiac echocardiography–guided implantation for proximal left bundle branch pacing.Circ Arrhythm Electrophysiol. 2023; 16:e011408. doi: 10.1161/CIRCEP.122.011408LinkGoogle Scholar12. Su L, Wang S, Wu S, Xu L, Huang Z, Chen X, Zheng R, Jiang L, Ellenbogen K, Whinnett Z, et al. Long-term safety and feasibility of left bundle branch pacing in a large single-center study.Circ Arrhythm Electrophysiol. 2021; 14:e009261. doi: 10.1161/CIRCEP.120.009261LinkGoogle Scholar13. Vijayaraman P, Ponnusamy S, Cano O, Sharma P, Naperkowski A, Subzposh F, Moskat P, Bednarek A, Dal Forno A, Young W, et al. Left bundle branch area pacing for cardiac resynchronization therapy. Results from the international LBBAP collaborative study group.JACC Clin Electrophysiol. 2021; 7:135–147. doi: 10.1016/j.jacep.2020.08.015CrossrefMedlineGoogle Scholar14. Vijayaraman P, Subzposh F, Naperkowski A, Panikkah R, John K, Mascarenhas V, Bauch T, Huang W. Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing.Heart Rhythm. 2019; 16:1774–1782. doi: 10.1016/j.hrthm.2019.05.011CrossrefMedlineGoogle Scholar15. Wu S, Chen X, Wang S, Xu L, Xiao F, Huang Z, Zheng R, Jiang L, Vijayaraman P, Sharma P, et al. Evaluation of the criteria to distinguish left bundle branch pacing from left ventricular septal pacing.JACC Clin Electrophysiol. 2021; 7:1166–1177. doi: 10.1016/j.jacep.2021.02.018CrossrefMedlineGoogle Scholar16. Lin J, Hu Q, Chen K, Dai Y, Chen R, Sun Q, Zhou Y, Yan L, Lu W, Li Y, et al. Relationship of paced left bundle branch pacing morphology with anatomic location and physiological outcomes.Heart Rhythm. 2021; 18:946–953. doi: 10.1016/j.hrthm.2021.03.034CrossrefMedlineGoogle Scholar17. Jastrzębski M, Kiełbasa G, Cano O, Curila K, Heckman L, De Pooter J, Chovanec M, Rademakers L, Huybrechts W, Grieco D, et al. Left bundle branch area pacing outcomes: the multicentre European MELOS study.Eur Heart J. 2022; 43:4161–4173. doi: 10.1093/eurheartj/ehac445CrossrefMedlineGoogle Scholar18. Salden F, Luerman J, Westra S, Weijs B, Engels E, Heckman L, Lamerichs L, Janssen M, Clerx K, Cornelussen R, et al. Short-term hemodynamic and electrophysiological effects of cardiac resynchronization by left ventricular septal pacing.J Am Coll Cardiol. 2020; 75:347–359. doi: 10.1016/j.jacc.2019.11.040CrossrefMedlineGoogle Scholar19. Li X, Zhu H, Fan X, Wang Q, Wang Z, Li H, Tao J, Wang H, Liu Z, Yao Y. Tricuspid regurgitation outcomes in left bundle branch area pacing in comparison with right ventricular septal pacing.Heart Rhythm. 2022; 19:1202–1203. doi: 10.1016/j.hrthm.2022.03.005CrossrefMedlineGoogle Scholar eLetters(0)eLetters should relate to an article recently published in the journal and are not a forum for providing unpublished data. Comments are reviewed for appropriate use of tone and language. Comments are not peer-reviewed. Acceptable comments are posted to the journal website only. Comments are not published in an issue and are not indexed in PubMed. Comments should be no longer than 500 words and will only be posted online. References are limited to 10. Authors of the article cited in the comment will be invited to reply, as appropriate.Comments and feedback on AHA/ASA Scientific Statements and Guidelines should be directed to the AHA/ASA Manuscript Oversight Committee via its Correspondence page.Sign In to Submit a Response to This Article Previous Back to top Next FiguresReferencesRelatedDetailsRelated articlesIntracardiac Echocardiography–Guided Implantation for Proximal Left Bundle Branch PacingXiaoHui Kuang, et al. Circulation: Arrhythmia and Electrophysiology. 2023;16 April 2023Vol 16, Issue 4 Advertisement Article InformationMetrics © 2023 American Heart Association, Inc.https://doi.org/10.1161/CIRCEP.123.011931PMID: 36951088 Originally publishedMarch 23, 2023 Keywordsleft bundle branch pacingintracardiac echoEditorialsbundle of Hisventricular septumPDF download Advertisement SubjectsArrhythmias
更多
查看译文
关键词
left bundle pacing,optimal lead placement,guidance
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要