Macroscale modeling of electrostatically charged facemasks

M. Jamali, S. Atri, S. Gautam, A. M. Saleh,H. V. Tafreshi,B. Pourdeyhimi

AEROSOL SCIENCE AND TECHNOLOGY(2023)

引用 2|浏览4
暂无评分
摘要
In this study, the instantaneous collection efficiency and pressure drop of an N95 facemask is numerically simulated in a setting similar (but not identical) to that used by NIOSH to certify N95 respirators. More specifically, a CPU-friendly macroscale model is developed, for the first time, to simulate the performance of an electrostatically-charged facemask when the mask is clean and when it is loaded with neutral or neutralized nanoparticles. The simulations were performed using ANSYS software enhanced with in-house subroutines, and they were calibrated using the experimental data reported in the literature for the initial efficiency of N95 masks. In addition, a correction factor was developed for the Kozeny-Carman permeability equation to expand its application to the case of nanoparticle-deposits, where the dendrites porosity is very high and the aerodynamic slip is expected to occur.Copyright (c) 2023 American Association for Aerosol Research
更多