Improved Measurements of Nonlinear Integrable Optics Invariants at IOTA

J. N. Wieland,A. L. Romanov, A. Valishev, G. Stancari, J. D. Jarvis, N. Kuklev,S. Szustkowski, S. Nagaitsev

arXiv (Cornell University)(2023)

引用 0|浏览1
暂无评分
摘要
Nonlinear integrable optics (NIO) are a promising novel approach at improving the stability of high intensity beams. Implementations of NIO based on specialized magnetic elements are being tested at the Integrable Optics Test Accelerator (IOTA) at Fermilab. One method of verifying proper implementation of these solutions is by measuring the analytic invariants predicted by theory. The initial measurements of nonlinear invariants were performed during IOTA run in 2019/20, however the covid-19 pandemic prevented the full-scale experimental program from being completed. Several important improvements were implemented in IOTA for the 2022/23 run, including the operation at higher beam energy of 150 MeV, improved optics control, and chromaticity correction. This report presents the results of improved measurements of nonlinear invariants.
更多
查看译文
关键词
nonlinear integrable optics invariants,iota
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要