Novel technique to prevent outflow tract obstruction in transapical transcatheter mitral valve replacement: The MitraCut technique.

JTCVS techniques(2023)

引用 0|浏览6
暂无评分
摘要
Central MessageThe MitraCut technique is an effective, safe, and unique surgical approach to prevent left-ventricular outflow tract obstruction in transapical transcatheter mitral valve replacement. The MitraCut technique is an effective, safe, and unique surgical approach to prevent left-ventricular outflow tract obstruction in transapical transcatheter mitral valve replacement. We present a novel technique to prevent left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve replacement (TMVR). Both reported patients were included in a local, prospective observational study (ERB No.: 1959/2020; November 6, 2022) to investigate the single-center outcome after transcatheter atrioventricular valve interventions. Patient 1 was a symptomatic (dyspnea, 4 heart failure hospitalizations) 88-year-old woman with severe degenerative mitral regurgitation (mechanism: A2 flail and moderate mitral annular calcification) (Figure E1) and anatomical contraindications for transcatheter edge-to-edge repair (mean pressure gradient [MPG] 6 mm Hg). The second patient was a 63-year-old, frail (among others: limited mobility due to repeated strokes) man with mixed severe mitral regurgitation (Carpentier IIIa) and previous thoracic endovascular aortic repair (TEVAR) (indication: perforating aortic ulcer in the aortic arch, TEVAR after transposition of the left subclavian artery, and reinsertion of the left vertebral artery), neither suitable for transcatheter edge-to-edge repair (MPG 7 mm Hg) nor for conventional mitral valve surgery due to the position of the proximal landing zone of the TEVAR hindering a conventional clamping of the ascending aorta. After thorough heart team discussions, transapical transcatheter mitral valve replacement (TMVR) with the Tendyne valve system (Abbott Medical) was considered the optimal therapeutic option in both patients. The annular dimensions were suitable for a 33S, low-profile (patient 1) and 29S, low-profile valve (patient 2), revealing an acceptable calculated end-systolic neo-LVOT (patient 1: 298 mm2 and patient 2: 296 mm2) (Figure E1). Nonetheless, the preinterventional echocardiographic evaluation indicated a risk for LVOT obstruction due to a long, rather untethered anterior mitral valve leaflet (AML), septal hypertrophy, and subsequent close AML-to-septum-distance in both patients (Figure E1), resulting in the procedural plan to split the AML by the MitraCut technique1Mach M. Kerbel T. Poschner T. Bartunek A. Sauer J. Laufer G. et al.Mitral leaflet cutting before transcatheter mitral valve replacement: the mitra-Cut technique.JACC Cardiovasc Interv. 2022; 15: 2107-2108Crossref PubMed Scopus (2) Google Scholar before TMVR. A neuroprotective deflection filter (TriGuard 3; Keystone Heart) was used due to calcifications in patient 1. A standard transapical access through a left minithoracotomy was performed and the guiding wire was placed in the left atrium after flossing with a pulmonary catheter.2Kerbel T. Mach M. Bartunek A. Coti I. Bartko P.E. Andreas M. Off-label transapical beating-heart transcatheter mitral valve replacement in severe mitral annular calcification.Multimed Man Cardiothorac Surg. 2022; 2022https://doi.org/10.1510/mmcts.2022.082Crossref PubMed Scopus (1) Google Scholar For the MitraCut, a 26Fr Gore DrySeal sheath (W.L. Gore & Associates, Inc) was shortened to 15 cm (Figure 1, A) and brought into the left atrium over the guiding wire. A straight endoscopic scissor (Ceramo HCR, MRT-2; Fehling Instruments) (length: 10 mm, shaft diameter: 5 mm) was inserted through the sheath and aligned (Figure 1, B and C). The sheet was retracted, the scissor was carefully moved in the left ventricle, the AML was caught at the mid-A2 part, and a sharp dissection of the A2 segment was performed in each patient with 1 cut (Figure 1, D and E), thus the transapical TVMR could be performed after removal of the large bore sheath. The skin-to-skin time was 97 minutes (patient 1) and 60 minutes (patient 2). In patient 1, the interventional result was a trace paravalvular leakage with no LVOT obstruction (MPG 1 mm Hg) despite an anterior motion of the AML (Figure 2, A and C). Patient 2 had a satisfactory TMVR result with no increase of the LVOT gradient (Figure 2, B and D). Both patients were transferred to the normal ward at the first postoperative day and discharged after an uneventful postoperative period at day 11 (patient 1) and day 8 (patient 2). The AML as a target to prevent LVOT obstruction in patients undergoing TMVR has been previously approached by the laceration of the anterior mitral leaflet to prevent LVOT-obstruction (LAMPOON) technique.3Babaliaros V.C. Greenbaum A.B. Khan J.M. Rogers T. Wang D.D. Eng M.H. et al.Intentional percutaneous laceration of the anterior mitral leaflet to prevent outflow obstruction during transcatheter mitral valve replacement: first-in-human experience.JACC Cardiovasc Interv. 2017; 10: 798-809Crossref PubMed Scopus (131) Google Scholar, 4Lisko J.C. Greenbaum A.B. Khan J.M. Kamioka N. Gleason P.T. Byku I. et al.Antegrade intentional laceration of the anterior mitral leaflet to prevent left ventricular outflow tract obstruction: a simplified technique from bench to bedside.Circ Cardiovasc Interv. 2020; 13e008903Crossref PubMed Scopus (23) Google Scholar, 5Lisko J.C. Babaliaros V.C. Khan J.M. Kamioka N. Gleason P.T. Paone G. et al.Tip-to-base LAMPOON for transcatheter mitral valve replacement with a protected mitral annulus.JACC Cardiovasc Interv. 2021; 14: 541-550Crossref PubMed Scopus (14) Google Scholar Transapical scissor-mediated splitting with the MitraCut technique was safe, effective, short, and highly controllable. In a setting of a preexisting apical access, the MitraCut technique might be superior to LAMPOON due to decreased risk for vascular complications.5Lisko J.C. Babaliaros V.C. Khan J.M. Kamioka N. Gleason P.T. Paone G. et al.Tip-to-base LAMPOON for transcatheter mitral valve replacement with a protected mitral annulus.JACC Cardiovasc Interv. 2021; 14: 541-550Crossref PubMed Scopus (14) Google Scholar Apical access side complications related to the MitraCut technique itself might be unlikely because the guiding sheath is significantly smaller than the inserted valve system (26Fr vs 34Fr). The MitraCut technique might not be suitable for transseptal TMVR. From our experience, we recommend a complete neuroprotection—also covering the left subclavian artery—in patients with calcifications.1Mach M. Kerbel T. Poschner T. Bartunek A. Sauer J. Laufer G. et al.Mitral leaflet cutting before transcatheter mitral valve replacement: the mitra-Cut technique.JACC Cardiovasc Interv. 2022; 15: 2107-2108Crossref PubMed Scopus (2) Google Scholar The MitraCut technique might be a valuable alternative to the LAMPOON technique and other techniques to prevent LVOT obstruction in patients with transapical TMVR. Further evaluation in a higher-volume study population is anticipated.
更多
查看译文
关键词
outflow tract obstruction,mitral,valve
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要