Superiority of integrated cervicothoracic immobilization in the setup of lung cancer patients treated with supraclavicular station irradiation

Bao Wan,Shihong Luo, Xin Feng, Wenhua Qin, Haifan Sun, Lu Hou, Kun Zhang, Shiyu Wu,Zongmei Zhou,Zefen Xiao,Dongfu Chen,Qinfu Feng,Xin Wang,Fukui Huan,Nan Bi,Jianyang Wang

FRONTIERS IN ONCOLOGY(2023)

引用 0|浏览0
暂无评分
摘要
ObjectiveTo investigate the superiority of the integrated cervicothoracic immobilization devices (ICTID) on the mobility of the supraclavicular station in lung cancer patients requiring both primary lung lesion and positive supraclavicular lymph nodes irradiation. MethodsOne hundred patients with lung cancer were prospectively enrolled in the study. The following four different fixation methods are used for CT simulation positioning: thoracoabdominal flat immobilization device fixation with arms lifting (TAFID group), head-neck-shoulder immobilization device fixation with arms on the body sides (HNSID group), ICTID fixation with arms on the body sides (ICTID arms-down group), and n ICTID fixation with arms lifting (ICTID arms-up group). Cone-beam computed tomography (CBCT) images are taken daily or weekly before treatment, to assess anatomical changes during the radiotherapy course. ResultsThe translation errors in X (left-right direction), Y (head-foot direction), and Z (abdomen-back direction) directions of the ICTID arms-up, TAFID, ICTID arms-down and HNSID groups were (0.15 +/- 0.18) cm, (0.15 +/- 0.16) cm, (0.16 +/- 0.16) cm, and (0.15 +/- 0.20) cm; (0.15 +/- 0.15) cm, (0.21 +/- 0.25) cm, (0.28 +/- 0.23) cm, and (0.27 +/- 0.21) cm; (0.13 +/- 0.14) cm, (0.15 +/- 0.14) cm, (0.17 +/- 0.13) cm, and (0.16 +/- 0.14) cm, respectively. Among them, the ICTID arms-up group had the minimal setup errors in X direction than those in ICTID arms-down (p=0.001) and HNSID groups (p=0.001), and in Y direction than those in TAFID (p<0.001), and in Z direction than those in ICTID arms-down (p<0.001) and TAFID groups (p=0.034). For the rotational errors of the four groups in the directions of sagittal plane, transverse plane, and coronal plane, the ICTID arms-up group had the smallest setup errors in the sagittal plane than that of TAFID groups and similar rotation setup errors with those of the other three groups. ConclusionFor patients requiring radiation of primary lung lesion and positive supraclavicular lymph nodes, an integrated frame fixation device is preferred the ICTID arms-up methods provide the smallest set up error and satisfied repeatability of body position, compared with TAFID and HNSID.
更多
查看译文
关键词
lung cancer, radiotherapy, positioning error, thoracoabdominal flat immobilization device, integrated cervicothoracic immobilization device
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要