Investigating the Antibacterial Effects of Synthetic Gamma-Lactam Heterocycles on Methicillin-Resistant Staphylococcus aureus Strains and Assessing the Safety and Effectiveness of Lead Compound MFM514.

Molecules (Basel, Switzerland)(2023)

引用 1|浏览3
暂无评分
摘要
Methicillin-resistant (MRSA) continues to be one of the main causes of hospital-acquired infections in all regions of the world, while linezolid is one of the only commercially available oral antibiotics available against this dangerous gram-positive pathogen. In this study, the antibacterial activity from 32 analogues of synthetic gamma-lactam heterocycles against MRSA was determined. Amongst screened analogues for the minimum inhibitory concentration (MIC) assay, compound displayed good inhibitory activity with MIC values of 7.8-15.6 µg/mL against 30 MRSA and 12 methicillin-sensitive (MSSA) clinical isolates, while cytotoxicity evaluations displayed a mean inhibitory concentration (IC) value of > 625 µg/mL, displaying a potential to becoming as a lead compound. In subsequent animal studies for , a single-dose oral acute toxicity test revealed an estimated mean lethal dose (LD) value of <5000 mg/kg, while in the mice infection test, a mean effective dose (ED) value of 29.39 mg/kg was obtained via oral administration. These results suggest that gamma-lactam carbon skeleton, particularly , is highly recommended to be evaluated further as a new safe and efficacious orally delivered antibacterial agent against MRSA.
更多
查看译文
关键词
acute toxicity,antibacterial,gamma-lactam,mice infection,oral anti-MRSA agent