Personalized Y-90-resin microspheres dose determination: a retrospective study on the impact of dosimetry software on the treatment of patients with selective internal radiotherapy

Nuclear medicine communications(2023)

引用 0|浏览5
暂无评分
摘要
Introduction The calculation of resin yttrium-90 (Y-90-) microspheres activity for selective internal radiotherapy (SIRT) needs to be investigated. Methods and materials Analyses using Simplicit(90)Y (Boston Scientific, Natick, Massachusetts, USA) dosimetry software were performed to determine the concordance between the absorbed doses to the tumor (D-T1 and D-T2) and healthy liver (D-N1 and D-N2) during the pre-treatment and the post-treatment phases. An optimized calculation of the activity of Y-90-microspheres performed using dosimetry software was applied retrospectively to assess the impact of this calculation method on the treatment. Results D-T1 ranged from 38.8 to 372 Gy, with a mean value of 128.9 +/- 73.6 Gy and median of 121.2 Gy [interquartile range (IQR): 81.7-158.8 Gy]. The median D-N1 and D-N2 was 10.5 Gy (IQR: 5.8-17.6). A significant correlation was between D-T1 and D-T2 (r = 0.88, P < 0.001) and D-N1 and D-N2 (r = 0.96, P < 0.001). The optimized activities were calculated; the target dose to the tumor compartment was 120 Gy. No activity reduction was applied in accordance with the tolerance of the healthy liver. Optimization of the microspheres dosages would have resulted in a significant increase in activity for nine treatments (0.21-2.54 GBq) and a reduction for seven others (0.25-0.76 GBq). Conclusions The development of customized dosimetry software adapted to clinical practice makes it possible to use dosimetry to optimize the dosage for each patient. Copyright (c) 2023 Wolters Kluwer Health, Inc. All rights reserved.
更多
查看译文
关键词
dosimetry software, hepatocellular carcinoma, Y-90 resin microspheres
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要