An Increase in the Signal-To-Noise Ratio of the Detected Terahertz Field in the CdTe Crystal With a Change in the Relative Angle between THz and IR Pulse Polarizations

V. S. Shumigai,E. N. Oparin,A. N. Tsypkin

BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE(2023)

引用 0|浏览10
暂无评分
摘要
A technique for optimizing the parameters of a standard time-resolved terahertz spectroscopy setup, which allows to increase the signal-to-noise ratio. Cadmium telluride (CdTe) cut along the (110) plane was used as a detecting crystal. A femtosecond solid-state ytterbium laser with a central radiation wavelength of 1050 nm was chosen as the pump radiation source. A study of detecting properties of an electro-optical CdTe crystal for three angles between polarizations of probing and terahertz pulses showed that the maximum signal-to-noise ratio is achieved at an angle of 90° between polarizations.
更多
查看译文
关键词
terahertz radiation,electro-optic detection,pulsed radiation,polarization