Target Balloon-Assisted Antegrade and Retrograde Use of Re-Entry Catheters in Complex Chronic Total Occlusions.

Journal of cardiovascular development and disease(2023)

引用 1|浏览6
暂无评分
摘要
Purpose, Retrograde recanalizations have gained increasing recognition in complex arterial occlusive disease. Re-entry devices are a well described adjunct for antegrade recanalizations. We present our experience with target balloon-assisted antegrade and retrograde recanalizations using re-entry devices in challenging chronic total occlusions. MATERIALS AND METHODS:We report data from a retrospective multicenter registry. Eligibility criteria included either antegrade or retrograde use of the OutbackTM or GoBackTM re-entry catheter in combination with a balloon as a target to accomplish wire passage, when conventional antegrade and retrograde recanalization attempts had been unsuccessful. Procedural outcomes included technical success (defined as wire passage though the occlusion and delivery of adjunctive therapy with <30% residual stenosis at final angiogram), safety (periprocedural complications, e.g., bleeding, vessel injury, or occlusion of the artery at the re-entry site, and distal embolizations), and clinical outcome (amputation-free survival and freedom from target lesion revascularization after 12-months follow-up). RESULTS:Thirty-six consecutive patients underwent target balloon-assisted recanalization attempts. Fourteen (39 %) patients had a history of open vascular surgery in the index limb. Fifteen patients were claudications (Rutherford Class 2 or 3, 21 presented with chronic limb threatening limb ischemia (Rutherford Class 4 to 6). The locations of the occlusive lesions were as follows: iliac arteries in 3 cases, femoropopliteal artery in 39 cases, and in below-the-knee arteries in 12 cases. In 15 cases, recanalization was attempted in multilevel occlusions. Retrograde access was attempted in 1 case in the common femoral artery, in the femoropopliteal segment in 10 cases, in below-the-knee arteries in 23 cases, and finally in 2 patients via the brachial artery. In 10 cases, the re-entry devices were inserted via the retrograde access site. Technical success was achieved in 34 (94 %) patients. There were 3 periprocedural complications, none directly related to the target balloon-assisted re-entry maneuver. Amputation-free survival was 87.8 % and freedom from clinically driven target lesion revascularization was 86.6 % after 12-months follow-up. CONCLUSION:Target balloon-assisted use of re-entry devices in chronic total occlusions provides an effective and safe endovascular adjunct, when conventional antegrade and retrograde recanalization attempts have failed.
更多
查看译文
关键词
SAFARI technique,chronic total occlusions,level of evidence: level 3,non-randomized follow-up study,peripheral arterial disease,re-entry devices,retrograde recanalizations,target balloon-assisted recanalizations
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要