Refractory Hypotension During Implantation of a 70 mL Total Artificial Heart in a Patient With Pectus Excavatum: A Case Report.

Seminars in cardiothoracic and vascular anesthesia(2023)

引用 1|浏览4
暂无评分
摘要
The Syncardia total artificial heart system is the only commercially approved durable device for treating biventricular heart failure patients awaiting heart transplantation. Conventionally, the Syncardia total artificial heart system is implanted based on the distance from the anterior aspect of the 10th thoracic vertebra to the sternum and the patient's body surface area. However, this criterion does not account for chest wall musculoskeletal deformities. This case report describes a patient with a pectus excavatum who developed compression of the inferior vena cava after Syncardia total artificial heart implantation and how transesophageal echocardiography guided chest wall surgery to accommodate the total artificial heart system.
更多
查看译文
关键词
biventricular heart failure,inferior vena cava obstruction,left pulmonary vein obstruction,pectus excavatum,rib disarticulation,total artificial heart