Outcomes after cryoballoon ablation of paroxysmal atrial fibrillation with the PolarX or the Arctic front advance pro: a prospective multicentre experience

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology(2023)

引用 13|浏览31
暂无评分
摘要
The study compared procedural efficacy and safety, and the 12 months AF recurrence, between the PolarX, a new cryoballoon recently available, and the AFA-Pro. We considered 267 consecutive patients undergoing a first cryoablation procedure for paroxysmal AF (137 PolarX, 130 AFA-Pro). The PolarX cryoballoon reaches lower temperatures than the AFA-Pro. A higher rate of transient phrenic nerve palsy was found in patients treated with the PolarX system. No significative differences have been showed in term of 1-year freedom of AF recurrences between the two cryoballoon systems. Aims The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. Methods and results This multicentre prospective observational study included 267 consecutive patients undergoing a first cryoablation procedure for paroxysmal AF (137 PolarX, 130 AFA-Pro). KM curves with the log-rank test was used to compare the 1-year freedom from AF recurrence between both groups. Multivariate Cox model was performed to evaluate whether the type of procedure (PolarX vs. AFA-Pro) had an impact on the occurrence of AF recurrences after adjustment on potentially confounding factors. The PolarX reaches lower temperatures than the AFA-Pro (LSPV 52 +/- 5, vs. 59 +/- 6; LIPV 49 +/- 6 vs. 56 +/- 6; right superior pulmonary vein: 49 +/- 6 vs. 57 +/- 7; right inferior pulmonary vein: 52 +/- 6 vs. 59 +/- 6; P < 0.0001). A higher rate of transient phrenic nerve palsy was found in patients treated with the PolarX system (15% vs. 7%, P = 0.05). After a mean follow-up of 15 +/- 5 months, 20 patients (15%) had recurrences in AFA-Pro group and 27 patients (19%) in PolarX group (P = 0.35). Based on survival analysis, no significant difference was observed between both groups with a 12-month free of recurrence survival of 91.2% (85.1-95.4%) vs. 83.7% (76.0%-89.1%) (log-rank test P = 0.11). In multivariate Cox model hazard ratio of recurrence for PolarX vs. AFA-Pro was not significant [HR = 1.6 (0.9-2.8), P = 0.12]. Conclusion PolarX and AFA-Pro have comparable efficacy and safety profiles for pulmonary veins isolation in paroxysmal atrial fibrillation.
更多
查看译文
关键词
Atrial fibrillation,Paroxysmal atrial fibrillation,Atrial fibrillation ablation,Cryoablation,Cryoballoon
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要