Automated oxygen control for very preterm infants and neurodevelopmental outcome at 2 years−a retrospective cohort study

European journal of pediatrics(2023)

引用 2|浏览1
暂无评分
摘要
Faster resolution of hypoxaemic or hyperoxaemic events in preterm infants may reduce long-term neurodevelopmental impairment. Automatic titration of inspiratory oxygen increases time within the oxygen saturation target range and may provide a more prompt response to hypoxic and hyperoxic events. We assessed routinely performed follow-up at 2 years of age after the implementation of automated oxygen control (AOC) as standard care and compared this with a historical cohort. Neurodevelopmental outcomes at 2 years of age were compared for infants born at 24–29 weeks gestational age before (2012–2015) and after (2015–2018) the implementation of AOC as standard of care. The primary outcome was a composite outcome of either mortality or severe neurodevelopmental impairment (NDI), and other outcomes assessed were mild-moderate NDI, Bayley-III composite scores, cerebral palsy GMFCS, and CBCL problem behaviour scores. A total of 289 infants were included in the pre-AOC epoch and 292 in the post-AOC epoch. Baseline characteristics were not significantly different. Fifty-one infants were lost to follow-up (pre-AOC 6.9% (20/289), post-implementation 10.6% (31/292). The composite outcome of mortality or severe NDI was observed in 17.9% pre-AOC (41/229) vs. 24.0% (47/196) post-AOC ( p = 0.12). No significant differences were found for the secondary outcomes such as mild-moderate NDI, Bayley-III composite scores, cerebral palsy GMFCS, and problem behaviour scores, with the exception of parent-reported readmissions until the moment of follow-up which was less frequent post-AOC than pre-AOC. Conclusion : In this cohort study, the implementation of automated oxygen control in our NICU as standard of care for preterm infants led to no statistically significant difference in neurodevelopmental outcome at 2 years of age. What is Known: • Neurodevelopmental outcome is linked to hypoxemia, hyperoxaemia and choice of SpO2 target range. • Automated titration of inspired oxygen may provide a faster resolution of hypoxaemic and hyperoxaemic events. What is New: • This cohort study did not find a significant difference in neurodevelopmental outcome at two years of age after implementing automated oxygen control as standard of care.
更多
查看译文
关键词
Hypoxemia,Hyperoxia,Closed-loop,Algorithm,Neonate,Respiratory,Follow-up
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要